Install the pop-up drain*

Remove the plunger assembly.
Unscrew the drain outlet flange from the tee.
Unscrew the tailpiece from the tee.  Wrap 

the threads with two layers of Teflon tape and 

replace. 
Install the white, flexible sealing gasket to the 

flange.  Place it in the sink outlet. 
From under the sink, install the black mack gas-

ket, white friction ring  and retainer nut  to the 

flange. Do not tighten the nut against the bottom 

of the sink at this time.
Thread the tee and tailpiece to the flange.  The 

pivot must face the faucet.  If necessary, turn the 

drain assembly.
Tighten the retainer nut.  
Place the plunger assembly in the drain. 
Install the horizontal rod so that the end goes 

through the loop in the bottom of the height 

adjuster.
Install and hand tighten the pivot ball nut.
Attach the swivel connector to the end of the 

horizontal rod.  
Attach the swivel connector to the end of the 

pull rod.   Position as desired and tighten with a 

small, flathead screwdriver.

*Drain and pull rod not included with models 34017XX1 

or 34027XX1.

plunger

flange

sealing gasket

mack gasket

friction ring

retainer nut

horizontal rod

height adjuster

pivot ball nut

swivel connector

pull rod

tee

tailpiece

Summary of Contents for Axor Citterio M 34010XX1

Page 1: ...Installation Instructions Warranty Axor Citterio M 34010XX1 34016XX1 34017XX1 Axor Citterio M 34120XX1 34127XX1 Axor Citterio M 34210XX1 ...

Page 2: ...4010XX1 34017XX1 34016XX1 34210XX1 Axor Citterio M Lav Mixer 34010XX1 Small Lav Mixer 34016XX1 Lav Mixer less Drain 34017XX1 Tall Lav Mixer 34120XX1 Tall Lav Mixer less Drain 34127XX1 Bidet Mixer 34210XX1 ...

Page 3: ...ous flow water heater if the flow pressure is at least 20 psi Technical Information Recommended water pressure 14 7 72 5 psi Max water pressure 145 psi Recommended hot water temp 120 140 F Max hot water temp 165 F Hole size in mounting surface 1 3 8 Max mounting surface depth 1 5 8 Flow rate 2 2 gpm Cartridge with high temperature limit stop 3 8 supply hoses requires 3 8 compression fitting not in...

Page 4: ...ition the faucet and sealing gasket on the mounting surface Install the fiber washer friction washer and mounting nut Tighten the mounting nut by hand Tighten the tensioning screws Drain and pull rod not included with models 34017XX1 or 34027XX1 ...

Page 5: ...op up drain Set the High Temperature Limit Stop optional Use a 3 mm Allen wrench to push the screw cover through the handle Use the Allen wrench to loosen the handle screw 2 complete revolutions Remove the handle Retrieve the screw cover Remove the flange Remove the high temperature limit stop Replace the high temperature limit stop so that the pin on the cartridge is in the desired slot on the li...

Page 6: ...e Replace the handle Tighten the handle screw Replace the screw cover Note the temperatures given in the diagram assume a water heater temperature of 140 F a cold water temperature of 50 F and a water pressure of 45 PSI ...

Page 7: ...lange The pivot must face the faucet If necessary turn the drain assembly Tighten the retainer nut Place the plunger assembly in the drain Install the horizontal rod so that the end goes through the loop in the bottom of the height adjuster Install and hand tighten the pivot ball nut Attach the swivel connector to the end of the horizontal rod Attach the swivel connector to the end of the pull rod...

Page 8: ... on by pushing the handle up Turn it off by pushing the handle down Pivot the handle to the left to make the water warmer to the right to make it cooler If the flow of water diminishes use the service key included to remove the aerator ...

Page 9: ...ce cartridge Replace O ring rings Water leaks at the connection hoses Connection hose defective O ring at the connection hose defective Cartridge adapter defective Cartridge adapter o ring defec tive Replace connection hose Replace O ring Replace cartridge adapter Replace O ring Hot water temperature too low no cold water High temperature limit stop in correctly set Set high temperature limit stop...

Page 10: ...apter for cartridge 98866000 7 aerator 98926000 8 pull rod 96657XX0 9 supply hose 470mm 96321001 supply hose 900mm 96316001 10 aerator service key 98987000 11 fixing set 13961000 12 ball joint 92036XX0 13 spray former 94005XX0 XX colors 00 chrome 82 brushed nickel 13 7 1 5 4 1 1 3 2 9 8 6 11 12 10 23x2 Replacement Parts ...

Page 11: ... to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime however please pay attention to the following points when cleaning faucets and showers Only use cleaning materials wh...

Page 12: ...e date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid ...

Reviews: