Installation
Maximum Hot Water Limit Setting
On delivery, the adjustable temperature
limiter (fitted as standard) is inoperative.
On applications requiring limiting the mixer
opening from full hot position, the adjustable
temperature limiter must be reset as de-
scribed below.
1.Lever out plug (O), see Fig. [11].
2.Remove set screw (P) with 3mm socket
spanner.
3.Pull off lever (R).
4.Unscrew cap (S).
5.Remove temperature limiter (M) and,
depending on the maximum water
temperature required, turn clockwise
(to increase temperature) or anticlock-
wise (to reduce temperature) and refit,
see Figs. [11] and [12].
6.Reinstall lever as described in Fig. [11] in
reversed direction.
Note:
A maximum temperature setting accurate to
the degree is not possible since differences
in hot and cold water flow temperatures,
pressure differences and installation con-
ditions all affect the temperature of mixed
water delivered at the outlet.