8
Activating cleaning mode,
see page 1.
Triggering flushing,
see page 1.
Making settings
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s.
Setting mode is automatically terminated after 3 minutes.
Setting the flow volume,
see page 2
Setting the programme,
see page 3
Maintenance
, see page 4
Power supply unit, see Fig. [3]
Solenoid valve, see Fig. [4]
Siphon with temperature sensor, see Fig. [5]
Elektronic, see Fig. [6]
Replacement parts
see fold-out page I
Disposal note
Fault / Cause / Remedy
Caution caused by magnetic field
Keep magnet away from electrical devices and
objects, which can be damaged by magnetic fields.
The safety data sheets for the product can be downloaded
from www.grohe.com/nachhaltigkeit.
This category of device does not belong in the
domestic waste, but must be disposed of separately
in accordance with the relevant national regulations.
Fault
Cause
Remedy
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
• Outlet clogged
• Temperature sensor defective
• Through high ambient temperature, the
water temperature in the siphon and in the
water supply is > 35 °C
• Flushing during continuous use is activated
(Flushing is initiated every 8 min.
independent of the use)
- Open shut-off valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Clean outlet
- Replace siphon with temperature sensor
- Ensure operating temperature of the water in the
water supply
- After drop of the temperature in the siphon the
elektronic terminates the mode flushing during
continuous use automatically
Undesired water
flow
• Automatic flushing activated
• Through high ambient temperature, the
water temperature in the siphon is > 35 ° C
• Solenoid valve defective
- The elektronic triggers a flushing to reduce the
water temperature in the siphon
- Replace solenoid valve
Flow volume too
low
• Solenoid valve defective
• Filter in solenoid valve blocked
- Replace solenoid valve
- Clean filter
Bluetooth
®
Connection not
possible
• No reception/connection interrupted
• Interferences in the reception area
• Obstacle in transmission path
- Turn back the device to receiving range
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path
Interrupted while
operating
• Interferences in the reception area
• Obstacle in transmission path
- Turn off the source of interference
(observe manufacturer´s documentation)
- Remove from radio path