Application

Thermostat mixers are designed for hot water supply via 
pressurised storage heaters and, utilised in this way, provide 
the best temperature accuracy. With sufficient power output 
(from 18 kW or 250 kcal/min), electric or gas instantaneous 
heaters are also suitable. 
Thermostats 

cannot

 be used in conjunction with 

non-pressurised storage heaters (displacement water 
heaters). 
All thermostats are adjusted in the factory at a flow pressure 
of 3 bar on both sides. 
Should temperature deviations occur on account of special 
installation conditions, the thermostat must be adapted to local 
conditions (see Adjusting).

Specifications

Minimum flow pressure without 
downstream resistances

0.5 bar

Minimum flow pressure with 
downstream resistances

1 bar

Max. operating pressure

10 bar

Recommended flow pressure

1 - 5 bar

Test pressure

16 bar

Flow rate at 3 bar flow pressure
Bath

approx. 20 l/min

Shower

approx. 26 l/min

Max. water temperature at hot water supply

80 °C

Recommended max. flow temperature (energy saving)

60 °C

Safety stop

38 °C

Hot water temperature at supply connection min. 2 °C higher 
than mixed water temperature
Cold water connection

right

Hot water connection

left

Minimum flow rate

= 5 l/min

If static pressure exceeds 5 bar, a pressure reducing valve 
must be fitted.

Installation

Flush pipes thoroughly.

Install S-unions and screw-mount the mixer, see fold-out page I, 
Fig. [1].
Refer to the dimensional drawing on fold-out page I.
The projection can be increased by 20mm with an extension, 
see Replacement Parts, fold-out page II and III, Prod. 
no. 07 130.

Adjusting

Temperature adjustment, 

see Figs. [2] and [3].

1. Open the shut-off valve and check the temperature of the 

water with a thermometer, see Fig. [2].

2. Lever out cap (A), see Fig. [3].
3. Remove screw (B).
4. Detach temperature control handle (C).
5. Turn regulating nut (D) until the water temperature has 

reached 38 °C.

6. Install temperature control handle (C) so that button (E) 

points towards the front, see Fig. [2].

7. Screw in screw (B), see Fig. [3].
8. Refit cap (A).

Temperature limitation

The safety stop limits the temperature range to 38 °C. The 38 °C 
limit can be overridden by pressing the button (E).

Adjusting the economy stop
Volume adjustment,

 see fold-out page I, Figs. [4] and [5].

• The flow rate is limited by a stop adjusted at the factory. If a 

higher flow rate is desired, the stop can be overridden by 
pressing the button (F), see Fig. [4].

To adjust the stop, proceed as follows:
1. Close shut-off valve.
2. Lever out cap (G).
3. Remove screw (H) and detach shut-off handle (J).
4. Remove splined adapter (K) and economy stop (L).
5. Reinstall economy stop (L) in the desired position. For 

adjustment range, see Fig. [5].

6. Fit splined adapter (K), see Fig. [4].
7. Fit shut-off handle (J) so that the button (F) points towards 

the front.

8. Screw in screw (H).
9. Refit cap (G).

Check operation of automatic diverter (M), 

see fold-out 

page IV, Figs. [6] and [7].
The diverter can be locked manually (advantageous at 
pressures below 0.5 bar, or for low discharge quantities). For 
this purpose, pull the diverter knob of diverter (M) and turn it 
anti-clockwise, see Fig. [7].

Prevention of frost damage

When the domestic water system is drained, thermostat 
mixers must be drained separately, since non-return valves 
are installed in the hot and cold water connections. For this 
purpose, the mixer must be removed from the wall.

Maintenance

Inspect and clean all parts, replace if necessary and lubricate 
with special valve grease (Prod. no. 18 012).

Shut off the hot and cold water supply.
I. Non-return valve (R) or (S), 

see fold-out page IV, Fig. [8].

• Remove connection nipple (P) by turning clockwise (left-hand 

thread) using a 12mm allen key.

Install in reverse order.

II. Thermostatic compact cartridge (U), 

see fold-out page IV, 

Fig. [9].
• Loosen screw ring (T) using a 34mm tool.
• If necessary, lever out thermostatic compact cartridge (U) 

via recess (U1).

• Remove screw ring (T).
Install in reverse order.

Observe the correct installation position of the 
thermostatic compact cartridge (U), 

see detail (U2).

Readjustment is necessary after every maintenance operation 
on the thermostatic compact cartridge (see Adjusting).

III. Ceramic headpart (V), 

see fold-out page IV, Fig. [10].

Install in reverse order.

IV. Diverter

, see fold-out page IV, Fig. [11].

Install in reverse order.

V. 

Unscrew and clean

 mousseur (13 927) 

see fold-out page II.

Replacement Parts, 

see fold-out pages II and III ( * = special 

accessories).

Care

For directions on the care of this fitting, refer to the 
accompanying Care Instructions.

Summary of Contents for 34 143

Page 1: ... F 1 S 3 PL 4 H 5 SLO 7 LV 8 E 2 DK 3 UAE 4 P 6 HR 7 LT 8 34 143 34 146 34 151 34 152 34 155 34 156 94 613 031 ÄM 201276 01 05 D 1 I 5 N 9 GR 13 TR 17 BG 21 RO 25 GB 2 NL 6 FIN 10 CZ 14 SK 18 EST 22 RUS 26 F 3 S 7 PL 11 H 15 SLO 19 LV 23 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 ...

Page 2: ... L 5 min max Please pass these instructions on to the end user of the fitting S v p remettre cette instruction à l utilisateur de la robinetterie Bitte diese Anleitung an den Benutzer der Armatur weitergeben 34 143 34 151 34 146 34 152 34 155 34 156 ...

Page 3: ...II ...

Page 4: ...n die 38 C Sperre überschritten werden Einstellen des Sparanschlages Mengen Einstellung siehe Klappseite I Abb 4 und 5 Die Wassermenge wird durch einen werkseitig eingestellten Anschlag begrenzt Wird eine größere Wassermenge gewünscht so kann durch Drücken der Taste F der Anschlag überschritten werden siehe Abb 4 Soll der Anschlag verstellt werden ist wie folgt vorzugehen 1 Absperrventil schließen...

Page 5: ...ridden by pressing the button E Adjusting the economy stop Volume adjustment see fold out page I Figs 4 and 5 The flow rate is limited by a stop adjusted at the factory If a higher flow rate is desired the stop can be overridden by pressing the button F see Fig 4 To adjust the stop proceed as follows 1 Close shut off valve 2 Lever out cap G 3 Remove screw H and detach shut off handle J 4 Remove sp...

Page 6: ...III ...

Page 7: ...IV 6 M 7 M 8 30mm 12mm O P R S 9 A B C T U 34mm U U1 U2 11 10 G H J K L V 17mm ...

Page 8: ...Grohe Water Technology AG Co KG Postfach 13 61 58653 Hemer Tel 0 23 72 93 0 Fax 0 23 72 93 12 22 ...

Reviews: