Application

Operation is possible in conjunction with:

Pressurized storage heaters

Operation is 

not

 possible with:

Low-pressure storage heaters (displacement water heaters)

Specifications

Max. flow:

      

 6.6 L/min or 1.75 gpm/ 60 psi

Flow pressure   
- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

Max. operating pressure                      

145 psi

Test pressure                                

232 psi

Temperature    
- max. (hot water inlet)                      

158 

°

F

- thermal desinfection possible

  Water connection:                                         cold - RH    hot - LH

Deck thickness max.

2 3/8"

Non reversible cartridge

Notes:

- Major pressure differences between cold and hot water supply 

should be avoided.

- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable appliances.

Installation

Flush piping system prior and after installation of faucet 
thoroughly! 

Mount sink faucet, 

see fold-out page III, Fig. [1].

Refer to the dimensional drawing on fold-out page I.

Feed the spray hose (A) through the faucet body from above, see 
Fig. [1].

Note:

If brace (B) is omitted, deck thickness can be increased by 1 3/4" to 
a total of 2 3/8".

Connect sink faucet,

 see Figs. [1] and [2].

- Cold water connection (marked blue)

= right

- Hot water connection (marked red)

= left

Avoid cross connection. The cartridge is not reversible.

Connect the spray hose (A),

 see Fig. [3].

1. Connect the handspray (C) without using any additional seals.
2. Fit one side of the stop (D) and spring (E) over the spray 

hose (A) from below.

3. Pass the end of the spray hose (A) through the other hole in the 

stop (D).

4. Install the snap coupling (G) on the end of the spray hose (A) and 

tighten by hand.

5. Push the sleeve (J) of the snap coupling (G) downwards and fit 

the coupling to the union (K).

To ensure that the handspray (C) is correctly seated when inserted, 
lug (L) and (M) on the outlet must engage in recess on the 
handspray.

Open cold and hot water supply and check connections for 
leakage!

Operation

1. Lever,

 see Fig. [4].

 

Slide lever to right  

= open (water flow)

Slide lever to left  

= closed

Slide lever towards front 

= cold water

Slide lever towards back  

= hot water

2. Handspray,

 see Fig. [5].

Slide lever to right (faucet open). The water will always emerge first 
from the aerator.
Diverter button:

Turning off the faucet automatically diverts the water flow from 
handspray to aerator.

Flow rate limiter

This faucet is fitted out with a flow rate limiter, permitting an 
infinitely individual variable reduction of the flow rate. The highest 
possible flow rate is set by the plant before despatch.

The use of flow rate limiters in combination with hydraulic 
instantaneous water heaters is not recommended.

To activate see “Replacing the cartridge” point 1 to 4, 
Figs. [6] and [7].

Maintenance

Inspect and clean all parts, replace as necessary and grease with 
special grease.

Shut off cold and hot water supply!

I. Replacing the cartridge,

 see fold-out page III, Fig. [6].

1. Lever out plug (N).
2. Loosen set screw (O) using a 3mm allen wrench.
3. Pull off lever (P).
4. Unscrew cap (R).
5. Turn out screwing (S) with wrench 32mm.
6. Change the complete cartridge (T).

Assemble in reverse order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the grooves and the 
locating pins at the base of the cartridge slot into the apertures on 
the housing. 
Screw in and tighten screwing (S).

II. Strainer and rose,

 see fold-out page III, Fig. [8].

1. Unscrew handspray (C) and remove non-return valve (U).
2. Pull out ring (V) and unscrew rose (W) by using wrench (X).
3. Clean strainer (Y) and rose (W).
4. Thanks to the SpeedClean nozzles, which must be regularly 

cleaned, limescale deposits on the rose can be removed by 
simply rubbing with the fingers.
The function of the SpeedClean nozzles is guaranteed for a 
period of five years.

Assemble in reverse order.

Replacement parts,

 see fold-out page II ( * = special accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Press 

Press 

 = switches from spray to aerator flow

 = switches to spray flow