Multiline AC
F219158R02
6
Release date: October 2019
INST
ALLA
TION
MANUAL
EN
Pump filling
Programming procedure of the AC pumps
• The AC pump can be filled either through the filler cap in the lid (1), or via the
grease nipple fill point (22). Initial filling should be made through the grease
nipple to prevent against any air pockets from occuring
in the pump chamber or
reservoir.
• Systems Lubricants & Filling Methods All Groeneveld Systems’ multiline pump
options are fitted as standard with both bulk top fill (suitable for oil and fluid
grease up to NGLI ‘000’) and bottom fill adaptors for filling of grease NGLI to Grade
2-this avoids the possibility of air entrapment. (for recommend lubricants see
Groeneveld installation manual for AC15XX & AC25XX page 6).
• If the reservoir must be filled through the reservoir cap molding (5), be certain
the cap (1) is secured to the reservoir cap molding (5) when finished. Take care to
prevent air pockets occuring in the reservoir.
The programmable AC15/AC25 has the following settings available:
Setting
Run time
Delay time
Total cycle time
0
Continuous
1
3 minutes
6 minutes
9 minutes
2
3 minutes
9 minutes
12 minutes
3
3 minutes
12 minutes
15 minutes
4
3 minutes
27 minutes
30 minutes
5
3 minutes
42 minutes
45 minutes
6
3 minutes
57 minutes
60 minutes