Principle of operation
22
Dat
e
of i
ss
u
e : J
a
nu
a
ry 2011
Automatic Greasing System
Twin-3
EG1703P03
2.8
Twin-3 display
With the switch-button (1) the desired operating/test mode can be selected and also errors can be
reset (see Figure 2.17). The Twin-3 display is equipped with a 3-digit display (2). Herewith errors,
the active duty mode and test mode (if applicable) can be displayed. The decimal dot (3) indicates
whether the interval timer remains or is on standby (see paragraph 2.8.1). The green LED (4)
indicates that the system is activated. The yellow LED (5) indicates when the minimum grease level
has been reached. The red LED (6) indicates a malfunctioning.
Figure 2.17
Twin-3 display
Proceed as follows to change the active duty mode:
1.
Switch ignition ON;
2.
Push the switch-button for at least 5 seconds.
Accordingly, the 3-digit display starts flashing;
3.
Push the switch-button repeatedly until the desired duty mode shows;
4.
Leave the desired duty mode flashing for at least 6 seconds until the duty mode comes on.
This will confirm the desired duty mode has now changed.
IMPORTANT
Do NOT switch OFF ignition when the desired duty mode still flashes. Otherwise, when ignition is
switched OFF proir to duty mode coming on, the change will be ignored and old duty mode
appears again.
6
5
4
3
2
1
TWIN
Automati
c
G
reasin
g
S
ystem
S
WIT
C
H
1. Switch-button
2. 3-digit display
3. Decimal dot
4. System activated indicator LED
5. Low grease level indicator LED
6. Alarm indicator LED