background image

This manual provides information for:

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

PART NUMBER 121066, REV. D (04/11)

MODELS TD/FPC 

Domestic

BRAISING PAN

· Stainless Steel
· Table Top Mounted
· Manual Tilting
· Electrically Heated
· 40 Quart Capacity

THIS  MANUAL  MUST  BE  RETAINED  FOR  FUTURE  REFERENCE.  
READ,  UNDERSTAND  AND  FOLLOW  THE  INSTRUCTIONS  AND 
WARNINGS CONTAINED IN THIS MANUAL.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

POST IN A PROMINENT LOCATION

Instructions to be followed in the event user smells 

gas.  This information shall be obtained by consulting 

your local gas supplier.  As a minimum, turn off the gas 

and call your gas company and your authorized service 

agent.  Evacuate all personnel from the area.

WARNING

Improper  installation,  adjustment,  alteration,  service 

or  maintenance  can  cause  property  damage,  injury  or 

death.  Read the installation, operating and maintenance 

instructions thoroughly before installing or servicing this 

equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

It is the responsibility of the consignee to inspect the container upon receipt of 
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a 
notation on the delivery receipt. It will be the responsibility of the consignee to file 
a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time 

of  printing/creation.    Unified  Brands  recommends  referencing  our  product  line  websites, 

unifiedbrands.net, for the most updated product information and specifications.

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

unifiedbrands.net

Summary of Contents for OM-BTD

Page 1: ...stallation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing...

Page 2: ...OR TRANSFER IS COMPLETE 5 DO NOT OVER FILL CONTAINER AVOID DIRECT SKIN CONTACT WITH HOT CONTAINER AND ITS CONTENTS WARNING DO NOT HEAT AN EMPTY PAN FOR MORE THAN FIVE MINUTES AT A SETTING HIGHER THAN...

Page 3: ...E SKIN EYES MUCOUS MEMBRANES AND CLOTHING READ THE WARNINGS AND FOLLOW DIRECTIONS ON THE CLEANER LABEL CAUTION NEVER LEAVE A CHLORINE SANITIZER IN CONTACT WITH STAINLESS STEEL FOR LONGER THAN 30 MINUT...

Page 4: ...og page 17 18 KLENZADE SALES CENTER ECOLAB Inc 370 Wabasha St Paul Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NF...

Page 5: ...the entire surface The heating elements and all other electrical components of the unit are enclosed for safety The thermostat and indicator light are contained in a compact control console mounted to...

Page 6: ...to avoid uneven cooking across the pan 2 Provide the proper electric power supply as specified on the electrical information plate Observe local codes and or The National Electrical Code in accordance...

Page 7: ...izontal position note how the water covers the pan bottom This is a good method to use for confirming that the unit is properly leveled 4 Set the thermostat to 235 F The heating indicator light should...

Page 8: ...steam to escape For longer simmering you may wish to close the vent to retain moisture 3 Be careful when lifting the optional cover Lift its rear edge a few inches to allow any steam or and hot vapor...

Page 9: ...he contactors close and the heaters and indicator light come on again This on off cycling continues holding the pan at the set temperature These cycles cause the indicator light to go on and off durin...

Page 10: ...r remote spots Clean between the pan body and the console using a brush 7 To remove materials stuck to the equipment use a brush sponge cloth plastic or rubber scraper or plastic wool with the cleanin...

Page 11: ...ical staff with laboratory facilities to serve you Maintenance Your Braising Pan is designed to require minimum maintenance but some parts may require replacement after prolonged use After installatio...

Page 12: ...rmostat dial setting Turn down if too high Authorized Service Rep Only b Thermostat functioning X c Thermostat calibration X d Contactor to determine if it is de energized X Pan does not reach desired...

Page 13: ...00 Watts 012843 5 Heater Strip 480 Volt 1000 Watts 012908 6 Transformer 380 Volt 001860 6 Transformer 480 Volt 012827 7 Fuse 1 AMP 480 Volt 004324 8 Contactor 208 240 Volt 1 Phase 009178 8 Contactor 2...

Page 14: ...MER MODEL Qty Part No Qty Part No Part No Part No 208 V 1 Ph 1 9178 6 12842 16028 None 208 V 3 Ph 1 9210 6 12842 16028 None 240 V 1 Ph 1 9178 6 12843 16028 None 240 V 3 Ph 1 9210 6 12843 16028 None 38...

Page 15: ...OM BTD FPC 15 Wiring Diagram...

Page 16: ...16 OM TD FPC Wiring Diagram...

Page 17: ...OM BTD FPC 17 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 18: ...18 OM TD FPC Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 19: ...OM BTD FPC 19...

Page 20: ...REV D 04 11 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2011 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: