Your Groen Braising Pan will operate smoothly and efficiently if properly maintained. However, the
following is a list of checks to make in the event of a problem.  If the actions suggested do not solve the
problem, call your qualified Groen Service Representative.  For the phone number of the nearest agency,
call your area Groen representative or the Groen Parts and Service Department.  If an item on the list is
followed by 

Y

, the work should only be performed by a qualified service representative.

WARNING

USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR
THEIR  AUTHORIZED  DISTRIBUTORS  CAN  CAUSE  INJURY  TO  THE  OPERATOR AND
DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES.  

SERVICE  PERFORMED  BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL
VOID ALL WARRANTIES.

SYMPTOM

 

WHO

WHAT TO CHECK

xindicates items which must be performed by an authorized technician.

Pan will not heat, but
indicator light comes on.

Auth Service
Rep Only

a.

Heating elements for short circuit.x

Pan will not heat, and
indicator light will not
light

User

a.

That power supply is on.

b.

Fuses, accessible by removing caps on the side of the
control box.

Auth Service
Rep Only

c.

For loose or broken wire.x

d.

Thermostat functioning, by listening for a click when the
switch opens or closes.x

e.

Contactor functioning.x

Pan continues to heat
after it reaches desired
temperature

User

a.

Thermostat dial setting

Auth Service
Rep Only

b.

Thermostat functioning, by listening for a click when the
switch opens or closes.x

c.

Thermostat calibration.x

d.

Contactor, to determine if it is de-energized.x

Pan does not reach
desired temperature.

User

a.

Thermostat dial setting.

Auth Service
Rep Only

b.

Heating elements for ground short or open (burned out)
element.x

c.

Thermostat functioning, by listening for a click when the
switch opens or closes.x

d.

Thermostat calibration.x

e.

Contactor functioning.x

Rapid clicking noise
(chattering)

User

a.

For low voltage.

Auth Service
Rep Only

b.

Contactor for dirt or corrosion on the contacts.x

Uneven cooking due to
“hot spots.”

User

a.

That the pan body is level

Uneven cooking due to
“cold spots.”

Auth Service
Rep Only

a.

For open (burned out) heating element.x

Pan will not tilt

User

a.

That electrical power supply is on.

b.

For overheated actuator motor.  Wait 15 minutes or less
for motor to cool, then operate the power tilt.  (For
instructions on manual operation see Page 7.

Auth Service
Rep Only

c.

For burned out capacitor or motor.x

Summary of Contents for NFPC series

Page 1: ...EL NFPC Braising Pan Stainless Steel Power Tilting Electrically Heated THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE READ UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANU...

Page 2: ...CONTACT WITH HOT FOOD OR WATER IN THE BRAISING PAN DIRECT CONTACT COULD RESULT IN SEVERE BURNS WARNING IF THE PAN CONTAINS ITEMS IN SAUCE OR MELTED FAT THEY COULD SLIDE FORWARD SUDDENLY DURING TILTING...

Page 3: ...MATICS 13 MAINTENANCE LOG 22 WARRANTY 23 References ECONOMICS LABORATORY INC St Paul Minnesota 55102 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The N...

Page 4: ...h on the front of the control console gives the operator positive smooth acting control of tilt Heating elements and other electrical components are enclosed for safety The thermostat heating indicato...

Page 5: ...ower line A BX connection is not recommended CAUTION ELECTRICALLY GROUND THE PAN AT THE TERMINAL PROVIDED 3 Provide the proper electrical supply as specified on the electrical plate attached to the eq...

Page 6: ...ermostat dial to the desired temperature between 100 and 400o F The glowing Heat Indicator Light shows that the pan is heating When the light cycles on and off it indicates that the pan is being held...

Page 7: ...the horizontal position pull the switch up 6 If the power tilt mechanism stops working See the Trouble Shooting Section and you must raise or lower the pan body without delay you can tilt the body man...

Page 8: ...for any reason a high limit thermostat shuts off the power until the pan cools At that point the thermostat automatically resets to permit normal operation to start again Turning the thermostat to OF...

Page 9: ...CONTROLSANDELECTRICALEQUIPMENT DO NOT SPRAY OR HOSE THE CONTROL B O X O R O T H E R E L E C T R I C A L CONNECTIONS THEY ARE NOT WATER PROOF b To remove any large amount of food left in the pan tilt t...

Page 10: ...tized and drained let all surfaces air dry unless the unit must be used again right away k It is recommended that the unit be sanitized just before use Follow the directions of the sanitizer supplier...

Page 11: ...ps on the side of the control box Auth Service Rep Only c For loose or broken wire x d Thermostat functioning by listening for a click when the switch opens or closes x e Contactor functioning x Pan c...

Page 12: ...nge Bracket 013485 5 Heater Strip 17 Bracket 004556 6 Fuse 6 Amp 003982 18 Actuator 045880 7 Fuse Holder 004326 19 Crank Manual Actuator 050242 8 Contactor Units after 1 1 85 006950 20 Thermostat Knob...

Page 13: ...13433 NFPC 4 NFPC 4 208V 1PH 208V 3PH 15 15 012842 012842 1 1 006950 013432 NFPC 4 NFPC 4 240V 1PH 240V 3PH 15 15 012843 012843 1 1 006950 013432 NFPC 4 380V 3PH 15 012843 1 013432 NFPC 4 NFPC 4 480V...

Page 14: ...OM NFPC 14 Wiring Diagrams...

Page 15: ...OM NFPC 15 Wiring Diagrams...

Page 16: ...OM NFPC 16 Wiring Diagrams...

Page 17: ...OM NFPC 17 Wiring Diagrams...

Page 18: ...OM NFPC 18 Wiring Diagrams...

Page 19: ...OM NFPC 19 Wiring Diagrams...

Page 20: ...OM NFPC 20 Wiring Diagrams...

Page 21: ...OM NFPC 21 Wiring Diagrams...

Page 22: ...OM NFPC 22 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed by...

Page 23: ...portal transportation costs time mileage for the first twelve 12 months from date of installation or fifteen 15 months from date of shipment from Groen IV This warranty does not cover boiler maintenan...

Page 24: ...1055 Mendell Davis Drive Jackson MS 39212 Telephone 601 372 3903 OM NFPC Revised 3 98 FAX 601 373 9587 Part Number 121009...

Reviews: