Model T10745
1
⁄
2
" x 18" Belt Sander
-6
-
section 2: poWer supply
Before installing the tool, consider the
availability and proximity of the required
power supply circuit. if an existing circuit
does not meet the requirements for this
tool, a new circuit must be installed. to
minimize the risk of electrocution, fire,
or equipment damage, installation work
and electrical wiring must be done by an
electrican or qualified service personnel
in accordance with all applicable codes
and standards.
full-load current rating
the full-load current rating is the amperage
a machine or tool draws at 100% of the
rated output power. on machines with
multiple motors, this is the amperage
drawn by the largest motor or sum of
all motors and electrical devices that
might operate at one time during normal
operations.
full-load current rating at 120v ........2a
the full-load current is not the maximum
amount of amps the tool will draw. if the
tool is overloaded, it will draw additional
amps beyond the full-load rating.
if the tool is overloaded for a sufficient
length of time, damage, overheating, or fire
may result—especially if connected to an
undersized circuit. to reduce risk of these
hazards, avoid overloading tool during
operation and make sure it is connected
to a power supply circuit that meets the
requirements in the following section.
electrocution, fire, or
equipment damage
may occur if tool is
not correctly ground-
ed and connected to
power supply.
serious injury could occur if you
connect the tool to power before
completing the setup process. do
not connect to power until instruct-
ed later in this manual.
120v circuit requirements
this tool is prewired to operate on a power
supply circuit that has a verified ground
and meets the following requirements:
voltage .............................................. 120v
cycle ................................................ 60 hz
phase .................................. single-phase
power supply circuit ................15 amps
a power supply circuit includes all
electrical equipment between the breaker
box or fuse panel in the building and the
tool. the power supply circuit used for this
tool must be sized to safely handle the
full-load current drawn from the tool for
an extended period of time. (if this tool is
connected to a circuit protected by fuses,
use a time delay fuse marked d.)
for your own safety and protection
of property, consult an electrician if
you are unsure about wiring practic-
es or electrical codes in your area.
note: The circuit requirements listed in this
manual apply to a dedicated circuit—where
only one machine or tool will be running at
a time. If this tool will be connected to a
shared circuit where multiple machines
or tools will be running at the same time,
consult a qualified electrician to ensure
that the circuit is properly sized for safe
operation.
Summary of Contents for T10745
Page 18: ...Model T10745 1 2 x 18 Belt Sander 16...
Page 20: ......