Grizzly T10687 Owner'S Manual Download Page 14

-12-

Model T10687 (Mfg. Since 10/12)

SECTION 2: POWER SUPPLY

Availability

Before installing the machine, consider the avail-
ability and proximity of the required power supply 
circuit.  If  an  existing  circuit  does  not  meet  the 
requirements for this machine, a new circuit must 
be installed. To minimize the risk of electrocution, 
fire,  or  equipment  damage,  installation  work  and 
electrical wiring must be done by an electrican or  
qualified service personnel in accordance with all 
applicable codes and standards.

Electrocution, fire, or 

equipment damage may 

occur if machine is not 

correctly grounded and 

connected to the power 

supply.

Full-Load Current Rating

The  full-load  current  rating  is  the  amperage  a 
machine draws at 100% of the rated output power. 
On  machines  with  multiple  motors,  this  is  the 
amperage drawn by the largest motor or sum of all 
motors  and  electrical  devices  that  might  operate 
at one time during normal operations.

Full-Load Current Rating at 120V ....... 9 Amps

The full-load current is not the maximum amount 
of amps that the machine will draw. If the machine 
is overloaded, it will draw additional amps beyond 
the full-load rating.

If the machine is overloaded for a sufficient length 
of time, damage, overheating, or fire may result—
especially  if  connected  to  an  undersized  circuit. 
To  reduce  the  risk  of  these  hazards,  avoid  over-
loading  the  machine  during  operation  and  make 
sure it is connected to a power supply circuit that 
meets the requirements in the following section.

For your own safety and protection of 

property, consult an electrician if you are 

unsure about wiring practices or electrical 

codes in your area.

Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one 
machine will be running at a time. If this machine 
will be connected to a shared circuit where mul-
tiple machines will be running at the same time, 
consult a qualified electrician to ensure that the 
circuit is properly sized for safe operation.

A  power  supply  circuit  includes  all  electrical 
equipment between the breaker box or fuse panel 
in the building and the machine. The power sup-
ply circuit used for this machine must be sized to 
safely handle the full-load current drawn from the 
machine  for  an  extended  period  of  time.  (If  this 
machine  is  connected  to  a  circuit  protected  by 
fuses, use a time delay fuse marked D.)

120V Circuit Requirements

This  machine  is  prewired  to  operate  on  a power 
supply circuit that has a verified ground and meets 
the following requirements:

Voltage ........................................................ 120V

Cycle ..........................................................60 Hz

Phase ........................................... Single-Phase

Power Supply Circuit ......................... 15 Amps

Serious injury could occur if you connect 

the machine to power before completing the 

setup process. DO NOT connect to power 

until instructed later in this manual.

Summary of Contents for T10687

Page 1: ...ufactured since 10 12 COPYRIGHT OCTOBER 2012 BY GRIZZLY INDUSTRIAL INC REVISED JUNE 2015 TR WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRI...

Page 2: ...g grinding tool integrity and the usage of personal protective equipment The manufacturer will not be held liable for injury or property damage from negligence improper training machine modifications...

Page 3: ...sing the Saw 16 Blade Selection 16 Changing Blades 16 Riving Knife Adjustment 17 Setting Cutting Depth 18 Setting Cutting Angle 19 Making Straight Cuts 19 Making Plunge Cuts 20 Using Rail Track 22 Add...

Page 4: ...be exact with the instruc tions specifications drawings and photographs of the tool we used when writing this manual However sometimes we still make an occasional mistake Also owing to our policy of c...

Page 5: ...tting operation Kickback An event in which the tool is propelled back towards the operator at a high rate of speed Parallel Being an equal distance apart at every point along two given lines or planes...

Page 6: ...nter the workpiece D Bevel Gauge Lock Knob Front Rear Sets the angle up to 45 at which the saw blade will cut into the workpiece and locks it into place E Rail Adjustment Knobs Allows for adjust ment...

Page 7: ...lunge cuts Also provides limited protection against accidental blade contact if kickback occurs L Saw Blade This saw is designed for a blade that has a 160mm diameter a 20mm arbor and is 2 2mm thick A...

Page 8: ...pe Universal Horsepower 1 1 KW Voltage 120V Phase Single Phase Amps 9A Speed 5500 RPM Cycle 60 Hz Main Specifications Blade Specifications Blade Diameter 160mm 61 4 Blade Tilt 0 45 Arbor Size 20mm Arb...

Page 9: ...ith Spring Loaded Riving Knife Low Profile Blade Guard for Cuts as Close as 5 8 from Wall 11 2 Dust Port for Efficient Dust Collection Versatile Saw can be Used With or Without Track Precision Depth C...

Page 10: ...y around children Make workshop kid proof DANGEROUS ENVIRONMENTS Do not use tools in areas that are wet cluttered or have poor lighting Operating tools in these areas greatly increases risk of acciden...

Page 11: ...dental contact with moving parts or flying debris Make sure they are properly installed undamaged and working correctly CHILDREN BYSTANDERS Keep children and bystanders at a safe distance from the wor...

Page 12: ...STOPPING AND RESTARTING CUTS Allow blade to reach full speed before cutting Complete all cuts when possible If a cut must be interrupted let blade come to a complete stop before removing saw Before r...

Page 13: ...to help prevent the most common causes of kickback Hold the saw firmly with both hands and position arms to help resist kickback forces Always stand to one side of the saw when operating never direct...

Page 14: ...undersized circuit To reduce the risk of these hazards avoid over loading the machine during operation and make sure it is connected to a power supply circuit that meets the requirements in the follo...

Page 15: ...eutral Hot When using extension cords make sure the cords are rated for outdoor use Outdoor use cords are marked with a W A or a W to signify their rat ing Always check to make sure that the extension...

Page 16: ...ials from around your saw and inspect it If you discover the machine is damaged please immediately call Customer Service at 570 546 9663 for advice Save the containers and all packing materials for po...

Page 17: ...how to book This machine creates substantial amounts of dust during operation Breathing air borne dust on a regular basis can result in permanent respiratory illness Reduce your risk by wearing a res...

Page 18: ...never use saw blades with bent or missing teeth or that appear damaged in any way The T10687 comes with a 48 tooth carbide tipped blade that will effectively handle most wood and wood like materials...

Page 19: ...Figure 11 for your reference Figure 11 Saw blade and blade fastening components Blade Washer Arbor Bolt Arbor Flange 7 Engage the blade lock to keep the arbor flange steady and tighten the arbor bolt...

Page 20: ...ent 5 Use a straightedge to verify that the riving knife is properly aligned with the blade If the two are misaligned then check that your blade thickness is not less than the thickness of the riving...

Page 21: ...ard Always wear safety glasses when using this machine There are generally two types of cuts made with this saw straight cuts and plunge cuts Straight cuts are made with the blade already extended wit...

Page 22: ...k in place Let the saw reach full speed before contact ing the workpiece Doing so will reduce the risk of kickback help provide the cleanest cut and reduce stress on the saw motor Keep fingers and han...

Page 23: ...he plunge release can be disen gaged Let the saw reach full speed before contact ing the workpiece Doing so will reduce the risk of kickback help provide the cleanest cut and reduce stress on the saw...

Page 24: ...provide a zero clearance effect which will help minimize splintering To set up the saw with the rail track 1 Align the rail track along the workpiece Use the right flat side of the rail track to plan...

Page 25: ...ecially useful when making plunge cuts Figure 24 Adjustable stop on rail track Adjustable Stop Figure 26 Stabilizer on rail track Stabilizer Figure 25 Stabilizer clipped over rail track Base Plate Rai...

Page 26: ...n whenever servic ing double insulated equipment to make certain repair does not destroy the insulated properties Service should be performed only by or under the guidance of qualified service personn...

Page 27: ...s 5 Test repair replace 6 Clean motor let cool and reduce workload 7 Test repair replace Tool has vibration or noisy operation 1 Motor or component loose 2 Blade at fault 3 Workpiece loose 4 Motor bea...

Page 28: ...can be adjusted using a 2 5mm hex wrench Figure 27 Location of zero stop set screw Zero Stop Set Screw To adjust the zero stop set screw 1 Place the saw on a flat level surface 2 Align the outside edg...

Page 29: ...ires may cause them to break or separate from terminal connectors Brush Wire Motor Wire Only Grasp Here When Disconnecting Terminals 7 Install replacement brushes in holders with wire side in down pos...

Page 30: ...0 71 71 71 72 72 73 73 74 74 75 75 76 76 77 78 79 80 82 11 T10687 OUTPUT HZ VOLT AMP RPM WEIGHT DATE SER NO 5500 11 LBS 60 9 1 1 KW T10687 Model 115 116 117 T10687 Track Saw Parts Breakdown SECTION 7...

Page 31: ...E TORSION SPRING 65 PT10687065 PHLP HD TAP SCR M4 X 14 22 PT10687022 POWER TORSION SPRING 66 PT10687066 ANGLE GAUGE POINTER 23 PT10687023 PHLP HD TAP SCR M3 X 8 67 PT10687067 PHLP HD TAP SCR M3 X 5 24...

Page 32: ...ION 101 PT10687101 BOTTOM RUBBER STRIP 107 PT10687107 ADJUSTABLE STOP BODY 102 PT10687102 BOTTOM FOAM STRIP 108 PT10687108 ADJUSTABLE STOP KNOB BOLT 103 PT10687103 RAIL TRACK BODY 109 PT10687109 F CLA...

Page 33: ...metalworker ____ 0 2 Years ____ 2 8 Years ____ 8 20 Years ____20 Years 6 How many of your machines or tools are Grizzly ____ 0 2 ____ 3 5 ____ 6 9 ____10 7 Do you think your machine represents a good...

Page 34: ...LINE FOLD ALONG DOTTED LINE GRIZZLY INDUSTRIAL INC P O BOX 2069 BELLINGHAM WA 98227 2069 Place Stamp Here Name_______________________________ Street_______________________________ City______________S...

Page 35: ...shall be tried in the State of Washington County of Whatcom We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arisi...

Page 36: ...Buy Direct and Save with Grizzly Trusted Proven and a Great Value Since 1983 ORDER 24 HOURS A DAY 1 800 523 4777 Visit Our Website Today For Current Specials...

Reviews: