g1006/7 heavy duty Mill/drill
-13-
serious personal injury could occur if you
connect the machine to power before com-
pleting the setup process. do not connect
the machine to the power until instructed
later in this manual.
110/220v operation
section 2: circuit reQuirements
full load amperage draw
amp draw at 110v (prewired) ................18 amps
amp draw at 220v ..................................9 amps
power supply circuit requirements
you Must connect your machine to a grounded
circuit that is rated for the amperage given below.
never replace a circuit breaker on an existing cir-
cuit with one of higher amperage without consult-
ing a qualified electrician to ensure compliance
with wiring codes.
if you are unsure about the
wiring codes in your area or you plan to con-
nect your machine to a shared circuit, consult
a qualified electrician.
Minimum Circuit size (110v) ................. 20 amps
Minimum Circuit size (220v) ................. 15 amps
power connection device
the Model g1006/7 comes prewired for 110v
and includes a neMa 5-15 plug. if you rewire the
motor to 220v, we recommend using the plug and
receptacle shown in
figure 2
for 220v.
electrocution or fire could
result if machine is not
grounded and installed in
compliance with electrical
codes. compliance must
be verified by a qualified
electrician!
extension cords
using extension cords may reduce the life of the
motor. instead, place the machine near a power
source. if you must use an extension cord:
•
For 110v, use at least a 10 gauge cord that
does not exceed 50 feet in length.
•
For 220v, use at least a 14 gauge cord that
does not exceed 50 feet in length.
• The extension cord must have a ground wire
and plug pin.
<gdjcY^c\Egdc\^h
Adc\Zhid[i]ZI]gZZ
Egdc\h
8jggZci
8Vggn^c\Egdc\h
<gdjcYZY
DjiaZi
figure 2.
recommended plug types.
5-15 plug
for 110v
6-15 plug & outlet
for 220v
NOTICE
the model g1006/7 is prewired for 110v
operation. if you plan to operate your
machine at 220v, the motor must be rewired
(see page 37).