-42-
Model G0793 (Mfd. Since 02/15)
READ ELECTRICAL SAFETY
ON PAGE 40!
To Upper
Elevation Limit
Switch
Page 47
To Chip Guard
Limit Switch
Page 47
To
Control Panel
Page 47
To Lower
Elevation Limit
Switch
Page 47
To
Coolant Pump
Page 49
To
Spindle Speed/
Direction Switch
Page 47
To
Power Connection
Page 44
To
Work Lamp
Page 44
30
31
E
L1 L2 L3 U1 V1
W1
U2 V2 W2 0
1
2
3
A
4
5
6
7
9
10
11
Master Power Switch
L
7
5
3
1
8 4
6 2
R
26
25
24
23
22
21
20
TC
20-21 = 220V
20-22 = 230V
20-23 = 240V
20-24 = 380V
20-25 = 400V
20-26 = 600V
Transformer
JBK5-100VATH
CanSen
LW26-20
ON
OFF
QM3
14
14
C6
DZ451-63
ON
OFF
QM2
D1
DZ451-63
ON
OFF
QM1
D10
DZ451-63
PE
L1 L2 L3
L1
L2
L3
L3
L2
L1
L2
L1
L3
A1
1L1
13NO
21NC
31NC
43NO
14NO
22NC
32NC
44NO
3L2
5L3
2T1
4T2
6T3
A2
KM1 Contactor
Siemens 3TB41 24V
A1
1L1
13NO
21NC
31NC
43NO
14NO
22NC
32NC
44NO
3L2
5L3
2T1
4T2
6T3
A2
KM2 Contactor
Siemens 3TB41 24V
2L1
ZL3
A1
13NO
23NO
33N0
43NO
14NO
24N0
34N0
44NO
A2
KA1 Contactor
Siemens 3TH80 24V
A1
13NO
23NO
33N0
43NO
14NO
24N0
34NO
44NO
A2
KA0 Contactor
Siemens 3TH80 24V
2L1
2L1
2L2
2L2
ZL3
ZL3
9
11
11
9
U1
U1
U1 V1
V1
V1
W1
W1
W1
0
0
0
0
0
PE
PE
6
6
5
5
6
4
3
3
4
6
2L2
2L2
3L1
3L1
3L3
3L3
2L1
2L1
ZL3
ZL3
3L3
3L1
U2
U2
V2
V2
W2
W2
U1 V1
W1
PE
12
13
13
12
1
1
0
U2 V2 W2
L1 L2 L3
11
7
7
1
6
7
PE
10
5
4
A
3
2
0
9
=For phase
converter wild
wire (if used)
Electrical Panel Wiring
Summary of Contents for G0793
Page 60: ......