-4-
Model G0711 (Mfg. Since 7/10)
Assembly & Setup
The Model G0711 requires a source of com-
pressed air that can consistently deliver 4 CFM at
50-100 PSI.
Since the Model G0711 must be lubricated before
each use, and at regular operating intervals, we
recommend using a filter/lubricator/regulator with
your compressed air line (see
Figure 6) below.
Quick
Connector
Quick
Coupler
Air Hose
Quick
Coupler
Quick
Connector
Lubricator
Filter
Regulator
Your
Tool
Air
Compressor
Figure
6
. Air line setup with filter/lubricator/regu-
lator installed.
Items Needed for Assembly
Qty
•
Hex Wrench 4mm ...................................... 1
•
Hex Wrench 5mm ...................................... 1
•
Fine Sand 40 Lb. Bag (Optional) ............... 1
2. Pull the hammer assembly spring loop to
the side and insert the hammer into the coil
spring, making sure the ring on the ham-
mer shaft is over the bottom spring loop, as
shown in
Figure 7.
3. Insert a die into the die housing, as shown in
Figure 9.
4. Raise the die housing up, and insert the pin
as shown in
Figure 10 to position the die
near the hammer.
The Model G0711 can also be filled with fine sand
to reduce vibration and noise during operation;
however, this is optional.
To assemble and set up the Model G0711:
1. Insert the hammer assembly into the top of
the C-frame assembly, position it as shown
in
Figure 7, and tighten the set screw.
Figure 7. Hammer installed in C-frame.
Set Screw
Figure 8. Hammer installed in spring.
Hammer
Spring
Loop
Ring
Figure 9. Die inserted.
Die
Figure 10. Pin inserted through bracket and
housing to position the die upward.
Pin