background image

-4-

Model G0711 (Mfg. Since 7/10)

Assembly & Setup

The  Model  G0711  requires  a  source  of  com-
pressed air that can consistently deliver 4 CFM at 
50-100 PSI.

Since the Model G0711 must be lubricated before 
each  use,  and  at  regular  operating  intervals,  we 
recommend using a filter/lubricator/regulator with 
your compressed air line (see 

Figure 6) below.

Quick 

Connector

Quick 

Coupler

Air Hose

Quick 

Coupler

Quick 

Connector

Lubricator

Filter

Regulator

Your

Tool

Air 

Compressor 

Figure 

6

Air line setup with filter/lubricator/regu-

lator installed.

Items Needed for Assembly 

Qty

• 

Hex Wrench 4mm ...................................... 1

• 

Hex Wrench 5mm ...................................... 1

• 

Fine Sand 40 Lb. Bag (Optional) ............... 1

2.  Pull  the  hammer  assembly  spring  loop  to 

the side and insert the hammer into the coil 
spring,  making  sure  the  ring  on  the  ham-
mer shaft is over the bottom spring loop, as 
shown in 

Figure 7.

3.  Insert a die into the die housing, as shown in 

Figure 9.

4.  Raise the die housing up, and insert the pin 

as  shown  in 

Figure  10  to  position  the  die 

near the hammer.

The Model G0711 can also be filled with fine sand 
to  reduce  vibration  and  noise  during  operation; 
however, this is optional.

To assemble and set up the Model G0711:

1.  Insert  the  hammer  assembly  into  the  top  of 

the  C-frame  assembly,  position  it  as  shown 
in 

Figure 7, and tighten the set screw.

Figure 7. Hammer installed in C-frame.

Set Screw

Figure 8. Hammer installed in spring.

Hammer

Spring 

Loop

Ring

Figure 9. Die inserted.

Die

Figure 10. Pin inserted through bracket and 

housing to position the die upward.

Pin

Summary of Contents for G0711

Page 1: ...Wear safety glasses and hearing protection while using this tool CRUSHING HAZARD Keep hands clear of ham mer at all times Specifications Control Power Pneumatic Throat Depth 195 8 Hammer Die Opening Usable 3 8 11 4 Maximum Opening Loading Unloading 4 Maximum Workpiece Thickness 5 64 2mm Hammer Speed 875 1350 BPM Operating Air Pressure 50 100 PSI Maximum Air Pressure 100 PSI Air Inlet Size Consumpt...

Page 2: ...DISCONNECT AIR PRESSURE before servic ing changing accessories or moving to another location Never leave this tool unattended when connected to air SECURE TOOLING Always verify tooling is secure before operation SHARP SURFACES DO NOT place hands near the tooling surfaces when in operation REMOVE ADJUSTING KEYS AND WRENCHES AFTER USE These tools become dangerous projectiles if left on the tool when...

Page 3: ...and Use 3 8 or 10mm diameter fasteners The length of the bolts screws will depend on the thickness of the workbench The type of fasteners required to install the planishing hammer will depend on how you choose to mount it The two most common options for mounting are the through mount and direct mount methods see Figures 4 5 below After the C frame has been positioned where you want to mount it tra...

Page 4: ...ammer assembly spring loop to the side and insert the hammer into the coil spring making sure the ring on the ham mer shaft is over the bottom spring loop as shown in Figure 7 3 Insert a die into the die housing as shown in Figure 9 4 Raise the die housing up and insert the pin as shown in Figure 10 to position the die near the hammer The Model G0711 can also be filled with fine sand to reduce vib...

Page 5: ...than the usual amount of lubrication you will use during maintenance The purpose of this is to load up the pneumatic components when they are new 8 Connect the air supply to the hose coming out of the foot switch see Figure Note There are many different styles of quick connect fittings If the air fitting supplied with the Model G0711 does not fit the style you have on your hose you will need to ma...

Page 6: ...ure between 50 100 PSI Hammer Speed Controls how fast and hard the hammer strikes the die while the foot switch is pressed This is measured in BPM s beats per minute Change this by adjusting the speed adjustment knob on the hammer assembly Figure 13 Die elevation lever Die Elevation Lever Die Hammer 4 Connect the air pressure and adjust the air supply PSI between 50 100 using your air regulator 5 ...

Page 7: ... your tools you ll appreciate these High Pressure Oil Cans Each can holds 5 ounces of oil and has a trigger activated high pressure pump T20881 In Line Lubricator 1 4 NPT T20882 Mini Regulator 1 4 NPT G6261 Water Filter 1 4 NPT Install an in line lubricator to apply oil automati cally Install an air regulator right at the tool for precise air control Install this filter in your air sup ply line to...

Page 8: ...LL PLUG 1 28 2 3 4 5 1 5 2 5 3 6 7 8 9 10 11 12 13 14 15 16 17 18 18 15 18 20 22 23 24 25 26 21 19 S p e c i f i c a t i o n s M O D E L G 0 7 1 1 P L A N I S H I N G H A M M E R W A R N I N G C R U SH IN G H A ZA R D K eep hands cle arofth e ham m erm echanis m at all tim es W A R N IN G EXPLOSION HAZARD Do not exceed 100 PSI when operating this machine WARNING R E A D a n d U N D E R S T A N D i...

Reviews: