Cord Rewired for 110V
Motor 220V
figure 10.
Cord rewired for 110V.
11.
use a phillips screwdriver to remove the
screws that secure the two metal jumpers
to the terminal block, as shown in
figure
9
,
then remove both jumpers. Be careful not to
mix up the locations of any of the wires while
you do so.
figure 9.
Changing motor jumper positions.
14.
install a neMa 5-20 plug such as the one
shown in
figure 3
onto the power cord, as
illustrated in
figure 10
. refer to
section
8: Wiring
starting on
page 45
for detailed
wiring diagrams.
12.
place both of the jumpers into the 110v loca-
tion shown in
figure
8
.
13.
replace the screws you removed in
step
11
, making sure all wires are secured in the
same positions they were originally in, as
shown in
figure 8
. refer to
section 8:
Wiring
starting on
page 45
for detailed wir-
ing diagrams.