-22-
Model G0619 (Mfd. Since 7/18)
To tilt the headstock to the left or right:
1. DISCONNECT THE MILL/DRILL FROM
POWER.
2. Using a 17mm wrench, loosen both head-
stock tilt acorn lock nuts (
Figure 16).
3. Insert a 6mm hex wrench into the index pin
release port (
Figure 16), and turn the hex
wrench clockwise to disengage the spring-
loaded index pin from the headstock.
4. While watching the tilt scale, rotate the head-
stock to the required angle, and retighten the
tilt acorn lock nuts to hold the headstock in
place.
Note: The index pin is spring loaded and
serves only as a quick way to return the
headstock close to zero. It is not intended to
be an absolute zero degree stop. No other
index holes exist at other angles in the head-
stock.
Figure 16. Headstock tilt controls.
Headstock Tilt
Acorn Lock Nut
Tilt Scale
Index Pin
Release Port
The table can be moved in the X-axis and Y-axis.
Longitudinal Feed
The longitudinal feed or (X-axis) is moved by the
handwheel shown in
Figure 17 at the end of the
table. The handwheel will move the table in both
directions side-to-side. One complete revolu-
tion of the handwheel moves the longitudinal
feed 0.100". There is also a scale on the front
of the table for use when a tight tolerance is not
required. The longitudinal feed can be locked in
position by a table lock located on the front of the
table (see
Figure 18).
Cross Feed
The cross feed or (Y-axis) in
Figure 17, is moved
with the handwheel on the front of the table base.
One complete revolution of the handwheel moves
the cross slide 0.100". The cross feed can be
locked into position by a table lock located on the
right side of the cross slide underneath the table
(see
Figure 18).
Figure 17. Table X and Y-axis controls.
Y-Axis Handwheel
X-Axis Handwheel
Figure 18. Table locks and scales.
X-Axis Table Lock Lever
X-Axis Scale
Y-Axis Table
Lock Lever
Y-Axis
Scale
Table Travel
(X-Axis and Y-Axis)
Summary of Contents for G0619