background image

Model G0572 (Mfd. Since 01/21)

-9-

Additional Safety for Air Filters

Long-term respiratory damage can occur from using this filter to capture hazardous dust 

without proper use of a respirator. Collecting flammable or combustible liquids, vapors, or 

explosive dusts can cause fire or explosions, resulting in smoke inhalation, serious burns, 

or death. An improperly secured air filter can fall, causing head injuries. To reduce the risk of 

these hazards, operator and bystanders MUST completely heed hazards and warnings below.

OPERATING LOCATION.  DO  NOT  operate  the 
air  filter  in  rainy  or  wet  locations—exposure  to 
water may create a shock hazard or decrease the 
life of the machine.

REGULAR CLEANING.  To  reduce  risk  of  start-
ing  fire,  regularly  clean  surrounding  area  where 
machine is operated. Excessive fine dust buildup 
on  overhead  lights,  heaters,  electrical  panels, 
or  other  heat  sources  can  increase  risk  of  fire. 
Regularly check/clean/change filters to avoid fine 
dust buildup.

EMPTYING DUST. To reduce exposure to wood 
dust when removing dust from filters, which may 
increase  risk  of  allergic  reactions  or  respiratory 
problems,  always  turn  switch 

OFF,  disconnect 

power, and wear a respirator and safety glasses. 
To  reduce  fire  and  explosion  risk,  empty  dust 
away from ignition sources and into an approved 
container.

SUSPENDED DUST PARTICLES AND IGNITION 

SOURCES.  To  reduce  risk  of  death  or  injury 
caused by explosions or fires, DO NOT operate fil-
ter in areas where these risks are high, including, 
but  not  limited  to,  spaces  near  pilot  lights,  open 
flames, or other ignition sources.

MOUNTING. To reduce risk of injuries due to fil-
ter falling, secure it to load-bearing joists or wall 
studs  that  can  support  its  weight.  Do  not  mount 
unit  only  to  sheet  rock,  pressboard,  paneling,  or 
honeycomb  ceiling  panels  with  expansion-type 
fasteners, which can easily tear out. 

LUNG PROTECTION. Fine dust that is too small 
to  be  caught  in  filter  will  be  blown  into  ambient 
air  during  operation.  Always  wear  a  NIOSH- 
approved  respirator  during  operation  and  for  a 
short time after to reduce your risk of permanent 
respiratory damage.

INTENDED USE.  Using  this  filter  regularly  to 
collect  prohibited  materials  can  result  in  serious 
health  problems.  It  is  only  designed  to  capture 
dust from ambient air in a woodworking shop for 
a  short  time  after  cutting  or  sanding  operations. 
DO NOT use to collect particles of silica, polyure-
thane, metal, lead paint, asbestos, or hazardous 
bacterium. DO NOT allow filter to collect explosive 
dusts, flammable, or combustible liquids or fumes, 
burning  or  smoking  material,  or  toxic  fumes.  DO 
NOT connect directly to air filtration system. Only 
operate with filters installed. 

HAZARDOUS DUST. Dust exposure may cause 
cancer,  birth  defects,  or  long-term  respiratory 
damage.  Be  aware  of  dust  hazards  associated 
with  each  workpiece  material,  and  always  wear 
a NIOSH-approved respirator to reduce your risk.

DUST ALLERGIES.  Dust  from  certain  woods 
may  cause  an  allergic  reaction  in  people  and 
animals. Make sure you know what type of wood 
dust you will be exposed to in case of an allergic 
reaction.

POWER DISCONNECT.  Turn  switch  OFF,  dis-
connect  air  filter  from  power  supply,  and  allow 
impeller to come to a complete stop before doing 
any cleaning, maintenance, or service.

Summary of Contents for G0572

Page 1: ...20 AI WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC BL6810 PRINTED IN CHINA V2 10 20 MODEL G0572 HANGING AIR FILTER WITH REMOTE OWNER S MANUAL For models manufactured since 01 21 4000909 ...

Page 2: ...ng grinding tool integrity and the usage of personal protective equipment The manufacturer will not be held liable for injury or property damage from negligence improper training machine modifications or misuse Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other repr...

Page 3: ... 12 Inventory 13 Hardware Recognition Chart 14 Test Run 15 Site Planning 16 Mounting Air Filter 17 SECTION 4 OPERATIONS 21 Operation Overview 21 Filtering Performance 21 SECTION 5 ACCESSORIES 22 SECTION 6 MAINTENANCE 23 Schedule 23 Cleaning Replacing Filters 23 SECTION 7 SERVICE 25 Troubleshooting 25 Replacing Fuse 26 Replacing Remote Control Batteries 26 SECTION 8 WIRING 27 Wiring Safety Instruct...

Page 4: ...ade every effort to be exact with the instruc tions specifications drawings and photographs in this manual Sometimes we make mistakes but our policy of continuous improvement also means that sometimes the machine you receive is slightly different than shown in the manual If you find this to be the case and the difference between the manual and machine leaves you confused or unsure about something ...

Page 5: ...ttention Use this machine with respect and caution to decrease the risk of operator injury If normal safety pre cautions are overlooked or ignored serious personal injury may occur No list of safety guidelines can be complete Every shop environment is different Always consider safety first as it applies to your individual working conditions Use this and other machinery with caution and respect Fai...

Page 6: ...st of the manual and minimize your risk of injury when operating this machine A Auto Shut Off Indicator Indicates if auto shut off is enabled and how long timer is set B Fan Speed Indicator Indicates if fan is oper ating at LO MID or HI speed C OFF Button Turns machine OFF D ON SPEED Button Turns machine ON If machine is ON cycles between fan speeds E Fuse Holder Unscrews for quick removal and rep...

Page 7: ...Height 22 x 28 x 18 in Electrical Power Requirement 120V Single Phase 60Hz Full Load Current Rating 4 2A Minimum Circuit Size 15A Connection Type Cord Plug Power Cord Included Yes Power Cord Length 6 ft Power Cord Gauge 18 AWG Plug Included Yes Included Plug Type 5 15 Switch Type Control Panel Remote Control Motors Main Horsepower 1 3 HP Phase Single Phase Amps 4 2A Speed 770 980 1100 RPM Type ODP...

Page 8: ... ongoing improvement efforts this information may not accurately describe items previously purchased PAGE 2 OF 2 Model G0572 Other Specifications Country of Origin China Warranty 1 Year Approximate Assembly Setup Time 1 Hour Serial Number Location ID Label Sound Rating 62 69 dB ISO 9001 Factory Yes Certified by a Nationally Recognized Testing Laboratory NRTL Yes ...

Page 9: ...d proof DANGEROUS ENVIRONMENTS Do not use machinery in areas that are wet cluttered or have poor lighting Operating machinery in these areas greatly increases the risk of accidents and injury MENTAL ALERTNESS REQUIRED Full mental alertness is required for safe operation of machin ery Never operate under the influence of drugs or alcohol when tired or when distracted For Your Own Safety Read Instru...

Page 10: ... moving parts or flying debris Make sure they are properly installed undamaged and working correctly BEFORE operating machine FORCING MACHINERY Do not force machine It will do the job safer and better at the rate for which it was designed NEVER STAND ON MACHINE Serious injury may occur if machine is tipped or if the cutting tool is unintentionally contacted STABLE MACHINE Unexpected movement dur i...

Page 11: ...lights open flames or other ignition sources MOUNTING To reduce risk of injuries due to fil ter falling secure it to load bearing joists or wall studs that can support its weight Do not mount unit only to sheet rock pressboard paneling or honeycomb ceiling panels with expansion type fasteners which can easily tear out LUNG PROTECTION Fine dust that is too small to be caught in filter will be blown...

Page 12: ...ersized circuit To reduce the risk of these hazards avoid over loading the machine during operation and make sure it is connected to a power supply circuit that meets the specified circuit requirements For your own safety and protection of property consult an electrician if you are unsure about wiring practices or electrical codes in your area Note Circuit requirements in this manual apply to a de...

Page 13: ...ord size gets longer and the gauge size gets smaller higher gauge numbers indicate smaller sizes Any extension cord used with this machine must be in good condition and contain a ground wire and matching plug receptacle Additionally it must meet the following size requirements Minimum Gauge Size 16 AWG Maximum Length Shorter is Better 50 ft Grounding Plug Requirements Figure 3 Typical 5 15 plug an...

Page 14: ... following items are needed but not included for the setup assembly of this machine This machine and its components are very heavy Get lifting help or use power lifting equip ment such as a forklift to move heavy items This machine was carefully packaged for safe transport When unpacking separate all enclosed items from packaging materials and inspect them for shipping damage If items are damaged ...

Page 15: ...ts are missing e g a nut or a washer we will gladly replace them or for the sake of expediency replacements can be obtained at your local hardware store Box 1 Figures 4 5 Qty A Model G0572 Hanging Air Filter 1 B Secondary Filter 1 Micron Bag Type 1 C Primary Filter 5 Micron Pleated Type 1 D AAA Batteries 2 E Rubber Feet 4 F Hand Held Remote Control Unit 1 G Flange Brackets 4 H Eye Bolts M6 1 x 20 ...

Page 16: ... 14 Model G0572 Mfd Since 01 21 Hardware Recognition Chart USE THIS CHART TO MATCH UP HARDWARE DURING THE INVENTORY AND ASSEMBLY PROCESS 5mm 5mm Flat Head Cap Screw ...

Page 17: ...achine BEFORE understanding its controls and related safety information DO NOT operate or allow others to operate machine until the information is understood To test run machine 1 Clear all setup tools away from machine 2 Place machine on stable surface such as a workbench that can support it 3 Connect machine to power supply 4 Press ON SPEED button to turn machine ON see Figure 6 Press ON SPEED t...

Page 18: ...o keep in mind when selecting a spot for the air filter Study your shop layout and try to determine the best location for the hanging air filter Air flow that is obstructed will cause a short cycle effect producing unsatisfactory results There must be a clearance of at least 3 ft from any obstructions in front and back of the unit Try to place the air filter in front of high dust producers like sa...

Page 19: ...raffic but still offers easy access to the switch and filters Mounting Air Filter You can install the air filter unit one of the following ways Table Top Mount Use the rubber feet and or the flush mount flange brackets see Figures 9 10 for a table top application Refer to Table Top Mount on Page 18 Hanging Mount Use the eye bolts see Figures 9 10 for a high ceiling application Refer to Hanging Mou...

Page 20: ...mounting refer to the Flush Mount procedure on Page 19 and install the air filter unit to the tabletop with the flush mount flange brackets Figure 11 Rubber feet correctly installed To install air filter for hanging mount operations 1 Install 4 chains cables or steel strapping lines to ceiling from capable ceiling joists or supports so lines hang 151 4 left to right and 241 2 front to rear and air...

Page 21: ...least 100 lbs DO NOT mount the unit only to sheet rock pressboard paneling or honeycomb wall panels with expansion type fasteners The fasteners can tear out and the air filter can fall Ignoring this caution can result in injury or property damage Tools Needed Qty Lag Bolts or Hex Bolts with Hardware 1 4 4 Open End Wrench 10mm 1 To install air filter for flush mount operation 1 Locate applicable lo...

Page 22: ... mounting holes 4 Attach 4 flange brackets to air filter with 8 M6 1 x 8 hex bolts 6mm lock washers and 6mm flat washers see Figure 16 5 With help of an assistant position air filter on wall or ceiling then screw or bolt air filter in place Figure 16 Flange correctly installed under lip This machine and its components are very heavy Get lifting help or use power lifting equip ment such as a forkli...

Page 23: ...alculate how many times per hour the room volume is recirculated through the air filter by dividing 60 minutes by the circulating time from Step 1 This will give you how many times an hour the air in the room is recirculated through the air filter Operation Overview When the Model G0572 is turned ON the fan motor starts on HI and then switches to the speed of your selection Air is drawn through th...

Page 24: ...ed service of your air filter Figure 17 Replacement filters for Model G0572 H9621 H9622 G9955 Benchtop Dual Fan Dust Filter Two separately switched fan motors can be used to draw a maximum 400 CFM of your dusty shop air through the 5 micron pleated filter Perfect for sanding and power caring the clear plastic hood helps to direct flow from the work area directly into the filter Figure 18 Model G99...

Page 25: ...ct machine from power before adjustments maintenance or service The amount of air filter operation has a direct bearing on when you must clean or replace the filters To maintain efficient operation check the filters approximately every 40 hours of use in light or moderately dusty environments In very dusty environments check the filters every eight hours of use Always wear a respirator when checki...

Page 26: ...econdary filter is dry place both filters in air filter housing and close filter retainer latch Figure 21 1 Micron secondary filter 3 Place primary filter in garbage bag and shake gently to remove dust 4 Visually inspect filter to see if it needs to be replaced To clean and replace filters 1 DISCONNECT MACHINE FROM POWER 2 Open filter retainer latch and remove primary filter see Figure 20 Figure 2...

Page 27: ...ct replace if at fault 8 Replace motor Machine stalls or is underpowered 1 Filters at fault 2 Motor overheated 3 Run capacitor at fault 4 Extension cord too long 5 Motor or motor bearings at fault 1 Clean replace filters Page 23 2 Clean motor let cool and reduce workload 3 Test repair replace 4 Move machine closer to power supply use shorter extension cord 5 Replace motor Machine has vibration or ...

Page 28: ... 1 DISCONNECT MACHINE FROM POWER 2 Remove fuse holder located on control panel see Figure 22 3 Remove old fuse from holder and install new fuse 4 Replace fuse holder Replacing Remote Control Batteries The remote control uses two AAA batteries To replace them slide the battery compartment cover down and off the remote see Figure 23 Insert the batteries in the proper direction and replace the cover ...

Page 29: ...nt at the time of printing but may not match your machine If you find this to be the case use the wiring diagram inside the motor junction box CAPACITORS INVERTERS Some capacitors and power inverters store an electrical charge for up to 10 minutes after being disconnected from the power source To reduce the risk of being shocked wait at least this long before working on capacitors EXPERIENCING DIF...

Page 30: ... ELECTRICAL SAFETY ON PAGE 27 Impeller Control Panel F5A250V Ground KC01 10 02A Fuse Motor 120V Run Capacitor 6MFD 450VAC Circuit Board Air Filter Housing Neutral Hot Ground 110 VAC 5 15 Plug Wiring Diagram Figure 24 Circuit board wiring ...

Page 31: ...6 17 18 19V2 20 21 22 23 24 25 26 27 28 30V2 31 56 57 32 33 34 35 36 37 38 39 40 41 42V4 44 46 47 48 49 52V3 53 54 55 Main SECTION 9 PARTS We do our best to stock replacement parts when possible but we cannot guarantee that all parts shown are available for purchase Call 800 523 4777 or visit www grizzly com parts to check for availability ...

Page 32: ... 38 P0572038 EXT TOOTH WASHER 4MM 12 P0572012 FLANGE BRACKET 39 P0572039 CONTROL PANEL PHLP HD SCR 13 P0572013 HEX BOLT M6 1 X 30 40 P0572040 PC BOARD SPACER 14 P0572014 FLAT WASHER 6MM 41 P0572041 PHLP HD SCR M3 5 X 6 15 P0572015 SLEEVE 42V4 P0572042V4 CONTROL PANEL ASSEMBLY V4 01 21 16 P0572016 SPACER 44 P0572044 PHLP HD SCR M4 7 X 10 17 P0572017 FLANGE 46 P0572046 STRAIN RELIEF 18 P0572018 LOCK...

Page 33: ...d plug becomes damaged promptly repair and protect cord from future damage 10 Do not use without filters in place 11 Prevent unauthorized use by children or untrained users restrict access or disable machine when unattended Specifications 4000909 grizzly com EXPLOSION HAZARD Do not expose to spray paint paint or other flammable fumes To reduce risk of death or serious injury read manual BEFORE usi...

Page 34: ......

Page 35: ...r for incidental contingent special or consequential damages arising from the use of our products The manufacturers reserve the right to change specifications at any time because they constantly strive to achieve better quality equipment We make every effort to ensure that our products meet high quality and durability standards and we hope you never need to use this warranty In the event you need ...

Page 36: ......

Reviews: