79
GB
Trouble shooting
Problem
Possible cause
Corrective action
Appliance
won‘t start
No mains power supply
Check the socket, cable, line, plug
and fuse and have them repaired
by a qualified electrician if neces
-
sary.
Worn out carbon brushes
Send in to Service Centre for re-
pair
Motor faulty
On/Off switch (
4) defective
The suction tubes (
17) and
collection bag ( 14), and/or
blower tubes (
9) and protec-
tive cover (
7) are not cor-
rectly mounted.
See the section on „Initial start-up“
Intermittent
operation
Internal loose contact
Send in to Service Centre for re-
pair
Power cable damaged
On/Off switch (
4) defective
Weak or no
suction power/
throughput
Collection bag (
14) is full
Empty collection bag
Collection bag (
14) is dirty
Clean collection bag
Impeller, blower or suction pipe
(
9/17) is clogged or blocked
see „
Removal of clogging
and blockage“
Impeller does
not move
Foreign body blocking the impel
-
ler
Remove the blockage (see „
Re-
moval of clogging and blockage
“)
Summary of Contents for ELS 3027 E