background image

23

ORDER DIRECTLY TODAY AT: 

www.BulbAmerica.com

 or CALL TOLL FREE 888-505-2111 

Summary of Contents for STELVIO CYM 300

Page 1: ...Istruzioni Owner s Manual STELVIO CYM 300 STELVIO CYM 300 HFT AD 3425 250W MSD GY9 5 AD 3426 250W MSD GY9 5 HFT AD3425 Rev 0 04 Nov 04 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888...

Page 2: ...mento via Radio solo per AD3226 11 5 0 MANUTENZIONE 11 6 0 INFORMAZIONI TECNICHE 12 7 0 PARTI DI RICAMBIO 12 INDEX INDEX Page 1 0 PACKING 13 2 0 SAFETY 13 3 0 INSTALLATION 13 3 1 Fitting the lamp 13 3...

Page 3: ...interni ed esterni La temperatura ambiente massima consigliata di 35 C Attenzione la temperatura della superficie esterna del proiettore pu raggiungere 90 C Attenzione lampada molto calda prima della...

Page 4: ...4 3 4 5 6 Lampada ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 5: ...3 2 Posizionamento del proiettore 3 3 Installazione dei filtri opzionali 5 1 2 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 6: ...3 4 Installazione del paraluce 3 5 Collegamento elettrico 6 CAVO 3X1 5 sez minima ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 7: ...IO CYM 300 deve avere settato il relativo dip switch su ON dip switch numero 2 del gruppo 1 6 Quando il proiettore STELVIO CYM 300 lavora in modo MASTER AUTOMATICO i dip switch numerati da 1 a 8 del g...

Page 8: ...o 1 6 i proiettori Slave devono avere tutti i dip switch settati su OFF Le specifiche DMX richiedono una opportuna resistenza di terminazione 100 120 ohm La resi stenza di terminazione deve essere ins...

Page 9: ...e dei cavi di segnale DMX 9 Cavo schermato 2 poli calza La calza GND non deve toccare parti metalliche Calza Data Data GND Sez min 0 35 mm ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE...

Page 10: ...ente settato il loro indirizzo secondo la tabella 1 I dip switch che danno l indirizzo al proiettore sono numerati da 1 a 9 Ogni proiettore occupa 4 canali Dip switch del gruppo 1 6 Dip switch numero...

Page 11: ...tenzione particolare infatti essendo certificato IP65 esso totalmente isolato dagli agenti esterni Per assicurare la massima funzionalit e la massima resa ottica si raccomanda comunque di attenersi al...

Page 12: ...co e la brochure promozionale del pro dotto sono disponibili su richiesta 12 Dimensioni max di ingombro proiettore L341 x P367 x H558 mm Peso proiettore 18 Kg Materiale della carcassa Alluminio Tensio...

Page 13: ...ture of the unit surface can reach 90 C Caution hot lamp Ensure that the lamp is cold before attempting to remove it wait for about 15 minutes Caution it is strongly recommended that a safety chain or...

Page 14: ...14 5 6 Lamp ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 15: ...3 2 Mounting position 3 3 Optional filters installation 15 1 2 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 16: ...3 4 4 leaf barndoor installation 3 5 Electrical connection 16 3X1 5 sez minimum cable section ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 17: ...TIC mode the dip switch of the STELVIO CYM 300 unit must be set to ON group 1 6 dip switch no 2 When the STELVIO CYM 300 unit works in MASTER AUTOMATIC mode the dip switches from no 1 to no 8 from the...

Page 18: ...group 1 6 dipswitch no 2 the Slave units must be set with all relevant dip switches in the OFF position The DMX specifications require a 100 120 ohm terminal resistor which must be fitted between the...

Page 19: ...3 DMX Cable Connection 19 2 pole shielded cable hose the hose GND must nottouch metal parts Hose Data Data GND Min sect 0 35 mm ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 21...

Page 20: ...p switches which set the projector address are those from no 1 to no 9 Each STELVIO CYM 300 uses 4 channels Group 1 6 dip switches Dip switch no 2 it selects the operating mode OFF DMX SLAVE ON master...

Page 21: ...hat are running different programmes 5 0 MAINTENANCE The STELVIO CYM 300 unit does not require special maintenance In fact as an IP65 certified item it is completely proofed against external agents Ho...

Page 22: ...es not include consumables Exploded views the electrical wire diagram the electronic layout and the advertising brochure are available on request 22 Size L341 x P367 x H558 mm Weight 18 Kg Body Alumin...

Page 23: ...23 ORDER DIRECTLY TODAY AT www BulbAmerica com or CALL TOLL FREE 888 505 2111...

Page 24: ...rer Via Bulgaria 16 46042 CASTEL GOFFREDO MN Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mail griven griven it ORDER DIRECTLY TOD...

Reviews: