background image

Jasper MK2 - Rev. 1.00

page 6 of 7

Configuration example - Monocable with connectors

A

B

I

dmx

C

D

F

E

A

B

I

dmx

C

D

A

G

A

B

I

dmx

C

D

H

A

C

I

Multy Chain Configuration  using Repower Box

Single Chain Configuration

Multy Chain Configuration  using DMX junction Box 

A - Power Input  CE ver. 220-240 Vac

B - DMX/RDM Controller

C - Start Line Box 

AL5058M - without connectors

D - Jasper MK2 

E - Connection Cable 

AL0148 L=1m

 

F - DMX Terminator - R 120 Ω

G - Repower Box  - 

AL5167M without connectors

H - DMX Junction Box  - 

AL5059M without connectors

 I - DMX Cable - 

AL0512

CE Colours

Brown
Blue
Yellow/Green
Red
Black
White

USE

Live
Neutral
Ground
DMX Data +
DMX Data -
DMX GND

Max. 

10A

 

per 
daisy chain

DMX cable type:

Use a DMX repeater on each 

32nd

 fixture of the 

daisy chain or in case the total DMX LINE length 
exceeds 300m (1000 ft)

Utilizzare un ripetitore DMX ogni 

32

 apparecchi 

della catena o se la lunghezza totale della LINEA 
DMX supera i 300 m (1000 piedi)

2x0.34 mm2 impedance 110Ω, 
capacity 43pF/m, resistance 50Ω/Km.

Tipo di cavo DMX:

Max. 

10A

 

per
catena

2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.

F

F

Configuration example - Monocable without connectors

A

B

I

dmx

C

D

K

F

E

A

B

I

dmx

C

D

K

F

A

G

A

B

I

dmx

C

D

K

H

A

C

I

F

Multy Chain Configuration  using Repower Box

Single Chain Configuration

Multy Chain Configuration  using DMX junction Box 

A - Power Input  CE ver. 220-240 Vac

B - DMX/RDM Controller

C - Start Line Box 

AL5058M - without connectors

D - Jasper MK2 

E - Connection Cable 

AL0148 L=1m

 

F - DMX Terminator - R 120 Ω

G - Repower Box  - 

AL5167M without connectors

H - DMX Junction Box  - 

AL5059M without connectors

 I - DMX Cable - 

AL0512

K - Heat-shrink tubing

CE Colours

Brown
Blue
Yellow/Green
Red
Black
White

USE

Live
Neutral
Ground
DMX Data +
DMX Data -
DMX GND

Max. 

10A

 

per 
daisy chain

DMX cable type:

Use a DMX repeater on each 

32nd

 fixture of the 

daisy chain or in case the total DMX LINE length 
exceeds 300m (1000 ft)

Utilizzare un ripetitore DMX ogni 

32

 apparecchi 

della catena o se la lunghezza totale della LINEA 
DMX supera i 300 m (1000 piedi)

2x0.34 mm2 impedance 110Ω, 
capacity 43pF/m, resistance 50Ω/Km.

Tipo di cavo DMX:

Max. 

10A

 

per
catena

2x0,34 mm2 impedenza 110Ω,
capacità 43pF / m, resistenza 50Ω / Km.

MAX 8 UNIT ( 10A)

MAX 8 UNIT ( 10A)

Summary of Contents for Jasper MK2

Page 1: ...e the right to change speci cations without prior noti cation Tel 39 0376 779483 E mail sales griven com Web www griven com AL5400 Dimensions Power consumption 195 W Nominal current 0 88A Power supply...

Page 2: ...interno dell apparecchiatura Disconnect power before any connection operation Togliere l alimentazione prima di effettuare qualsiasi operazione di connessione tra gli apparecchi Check voltage and freq...

Page 3: ...GND Terra POWER DMX IN POWER DMX OUT Tipo di cavo C Monocavo connettori Tipo di cavo M Monocavo senza connettori RED DMX BLACK DMX WHITE COMMON ROSSO DMX BIANCO COMUNE NERO DMX BLUE N Neutral BROWN L...

Page 4: ...can accept the following RDM commands Discovery Upon request of the RDM controller the fixture signals its own presence the RDM controller will display the fixture on a list DMX address reading and s...

Page 5: ...ER 5 10 20 40 40 20 10 5 001 SLAVE FIXTURE SETTING OK FLASH FLASH FLASH FLASH 2x FLASH 3x FLASH 4x FLASH 4x FLASH 3x FLASH 2x FLASH FLASH FIXED COLOR MODE 0 100 100 0 5 inactivity Automatic LOGOUT Gre...

Page 6: ...o DMX Max 10A per catena 2x0 34 mm2 impedenza 110 capacit 43pF m resistenza 50 Km F F Configuration example Monocable without connectors A B I dmx C D K F E A B I dmx C D K F A G A B I dmx C D K H A C...

Page 7: ...res AL5058 C Start Line Box Mains Power AL5169 DMX terminator other Jasper fixtures AL5058 C Start Line Box DMX cable Mains Power AL5169 DMX terminator other Jasper fixtures AL5058 C Start Line Box Ma...

Reviews: