background image

Capital

User Manual

600

Rev.1.0
Date: 31/08/2020

page 1 of 12

Griven

 S.r.l. - Via Bulgaria, 16

46042 Castel Goffredo
Mantova -  Italy

© Copyright Griven 2020 - GRIVEN S.r.l. is continuously 
developing and improving all its products. 
We reserve the right to change specifications without 
prior notification

Tel. +39.0376.779483
Fax +39.0376.779682
E-mail: [email protected]
Web: www.griven.com

551090

Dimensions

 

20 3/8"

517mm  

 

29 3/4" 756mm

 

 

5 7/8"

150mm 

Capital 600

Capital 600 US

Capital 600 MC

Code

AL5020 - AL5022 (PE)

AL5024 (US) - AL5025 ( US PE)

AL5021 - AL5023 (PE)

Power consumption

2x 256 W(RN), 2x 285 W (W) 2x 266 (MC)

Nominal current 

2x 1.6 A (RN), 2x 1.29 A(W), 2x1.2(MC)

Power supply

100-277VAC 50-60Hz

Inrush current

2x 70 A@240VAC, cold start

Power factor 

cos.

φ

= 0.96 (RN&W), 0.94(US)

Electrical class

I

Weight

32.8  Kg

Operating temperature

-40°C to +50°C ( -40°F to 122°F )

IP rating

IP67

IK rating

IK09

Summary of Contents for AL5020

Page 1: ...2 E mail sales griven com Web www griven com 551090 Dimensions 20 3 8 517mm 29 3 4 756mm 5 7 8 150mm Capital 600 Capital 600 US Capital 600 MC Code AL5020 AL5022 PE AL5024 US AL5025 US PE AL5021 AL502...

Page 2: ...electrical system can reduce the risk of damage The use of an adequate magnetothermic switch along the power supply line is recommended Connect the fixtures one to each other only when disconnected fr...

Page 3: ...Capital Rev 1 0 page 3 of 12 Installation 1 2 12 50mm 6 7 8 175mm 6 7 8 175mm 1 2 12 50mm 35 10 10 Vertical beam aiming A A size 13 ISO Wrench 100 100 30 100 30 both screws both screws both screws A A...

Page 4: ...DALI Out DMX IN OUT DALI IN OUT RED DMX BLACK DMX WHITE COMMON RED DMX BLACK DMX WHITE COMMON Blue N Neutral Brown L Live Yellow Green GND MAINS 100 277VAC 50 60Hz DMX IN OUT RED DALI bus BLACK DALI...

Page 5: ...OWER DMX IN POWER DMX OUT POWER DMX IN POWER DMX OUT POWER DMX IN OUT POWER DMX IN OUT Blue N Neutral Brown L Live Yellow Green GND RED DMX BLACK DMX WHITE COMMON Blue N Neutral Brown L Live Yellow Gr...

Page 6: ...12 OK FLASH FLASH FLASH FLASH OK FLASH FLASH OK MASTER SLAVE AUTOMATIC MODE TO BE USED ONLY WITH DMX MODE 1 AUTOMATIC MASTER 5 10 20 40 40 20 10 5 001 SLAVE FIXTURE SETTING OK FLASH FLASH FLASH FLASH...

Page 7: ...255 6 No Strobo 0 5 0 100 Strobo 6 250 100 Strobo 251 255 4 IR 7 1 0 100 Red 0 255 2 0 100 Green 0 255 3 0 100 Blue 0 255 4 0 100 White 0 255 5 NO FUNCTION 0 5 2700K 6 7 2700K 3000K 8 40 3000K 41 42...

Page 8: ...te 64 79 Store DTR as Scene 0 15 80 95 Remove from Scene 0 15 96 111 Add to Group 0 15 112 127 Remove from Group 0 15 128 Store DTR as Short Address 144 Query Status 145 Query Ballast 151 Query Versio...

Page 9: ...ion Box M or C type cable A A A A Max 10 A per daisy chain Use a DMX repeater on each 16th the total DMX LINE length exceeds 300m 1000 ft Max 10 A per daisy chain Use a DMX repeater on each 16th the t...

Page 10: ...along the line The POLAR Edition is fitted with a thermal frontal glass which is particularly useful for outdoor applica tions In fact by warming up the glass melts ice and snow which might interfere...

Page 11: ...Capital Rev 1 0 page 11 of 12...

Page 12: ...Capital Rev 1 0 page 12 of 12...