background image

T

emperaTure

 C

ompensaTion

The charger is equipped with temperature compensation technology, 

which alters the charging parameters based on ambient temperature. 

This is beneficial for battery health, as it is critical in achieving an optimal 

charge because the battery’s needs change based on temperature. 

B

aTTery

 F

aulT

 p

roTeCTion

Guards against excessively charging compromised batteries. ERROR 

and CHARGING LED will flash indicating charging has stopped and the 

charger has detected a compromised battery. Conditions that cause this 

error include: if the battery voltage does not rise appropriately during the 

charging process (indicating a shorted cell) or if the maximum charge 

time has been exceeded.

s

horT

 C

irCuiT

 p

roTeCTion

Guards against shorted connections. ERROR LED will light solid on 

control panel and power will not be sent to output cables. This condition 

is triggered if the charger detects less than 1V across the clamps. See 

Operating Instructions Step 3 Note 2 for details regarding this feature. 

o

ver

-v

olTage

 p

roTeCTion

Guards against charging errors where the charger is programmed to 

charge in a different voltage than the detected voltage of the battery. 

When this safeguard is engaged, the ERROR indicator will light. To reset 

the charger, disconnect from AC outlet, reset the vehicle connections and 

reconnect to the AC outlet.

r

eCovery

 m

ode

The charger is equipped with the ability to react to the interruption of 

power (power outage) in two different ways. 

The factory default setting is Recovery Mode ON, under which the charger 

will continue to monitor the battery during a power outage situation 

and resume charging under the existing charging parameters upon the 

resumption of AC power. This feature is best utilized during periods when 

occasional monitoring of the charger is not possible, such as when you 

are on vacation. 

You can switch to Recovery Mode OFF, which turns the charger OFF if 

there is any interruption of AC input power. So, if the power goes out, the 

charger will stop charging and enter Standby Mode, with default settings, 

upon the resumption of AC power.  

To switch Recovery Mode from OFF to ON or ON to OFF, press and 

hold both the Battery Type and CHARGE button and push the Voltage 

Selection button twice. Recovery Mode status is indicated by the RM LED 

– when the RM LED is lit, Recovery is ON. 

When the charger is in Recovery Mode ON and a power interruption 

occurs, all charger status LEDs will turn off, except the RM LED, which will 

blink. After 36 hours, to conserve the charge on the connected battery, all 

LEDs will turn off. Upon resumption of power, the charger will resume 

normal operation in the existing settings and status indicators will again 

be active.

Have fun in your garage!

®

ANSWERS TO YOUR QUESTIONS

Should you have any comments or questions about the use of your Battery Manager V, our Customer Service Department can be reached 

by phone at 800-345-5789 or by email at [email protected]. For a complete selection of products or to receive a free 

G

riot

'

s

 G

araGe

 

Handbook, please call us or visit us at www.griotsgarage.com.

Griot's Garage, Inc.

®

 • 3333 South 38th Street • Tacoma, WA 98409 • 800-345-5789 • www.griotsgarage.com 

© 2014 Griot’s Garage, Inc.

®

 All rights reserved.

Summary of Contents for Battery Manager V

Page 1: ...12Vdc 4 0A 6Vdc 4 0A Cable Clamps Reconditions Dead Weak Batteries Hard Wire Mount Use With 6V Or 12V Batteries Battery Manager IV Cable Adapter Recovery Mode Resumes Charging After Power Failure Cigarette Lighter Adapter Read rear warning label Battery Volts Selector Battery Type Selector Start Stop Selector Reverse Polarity Indicator Error Indicator Recovery Mode Indicator Power Indicator Batter...

Page 2: ... the area around battery is well ventilated while battery is being charged Make sure there is no gasoline or other combustible material in the vicinity 3 Clean battery terminals with a mixture of baking soda and hot water Be careful to avoid corrosion coming in contact with eyes 4 Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge e...

Page 3: ... s protection by holding down the CHARGE button for 3 seconds The charger will commence the charging sequence and assuming there are no other hindrances that caused the fault indication will complete the charging process and automatically turn off when the battery has reached full charge 4 When the battery approaches full charge and enters the Completion Phase the green FULL CHARGE indicator will ...

Page 4: ...ecovery Mode ON under which the charger will continue to monitor the battery during a power outage situation and resume charging under the existing charging parameters upon the resumption of AC power This feature is best utilized during periods when occasional monitoring of the charger is not possible such as when you are on vacation You can switch to Recovery Mode OFF which turns the charger OFF ...

Reviews: