Page 6
Model FDD2500
Programming Machine from Touchpads (cont.)
9) Press (>) to modify
Auger Delay.
a) Press (>) and select dispense button.
b) Press the dispense button for the dispense head that you want to change the auger ON delay time.
c) Press (+) or (-) to modify the time in tenths of a second.
10) Press (>) to modify
Auger Off Delay.
a) Press the dispense button for the dispense head that you want to change the auger OFF delay time.
b) Press (+) or (-) to modify the time in tenths of a second.
11) Press (>) to change
Heater
settings.
(8A)
Press (+) or (-) to toggle between ON (water tank heater ON) and OFF (water tank heater OFF).
12) Press (>) to modify
Water Tank Temperature. (7A)
Press (+) or (-) to increase or decrease water tank temperature.
13) Press (>) to modify
Low Temp/No Brew
settings.
(7B)
Press (+) or (-) to toggle between ON (will not allow drinks to dispense if water temperature is below
programmed temperature) and OFF.
a) If turned ON press (>) to modify Minimum Dispensing Temp.
b) Press (+) or (-) to increase or decrease Minimum Dispensing Temp.
14) Press (>) to change
Sleep Mode
settings.
(8A)
Press (+) or (-) to toggle between OFF and ON (forces the water tank temperature to a programmed temperature
after a programmed time of inactivity – used for energy savings).
a) If turned ON, press (>) to change Sleep Mode Settings.
b) Press (+) or (-) to increase or decrease the amount of time the unit is inactive before going into sleep mode.
c) Press (>) to change sleep mode water tank temperature setting.
d) Press (+) or (-) to increase or decrease the water tank temperature during sleep mode.
15) Press (>) to view
Manual Dispense
mode.
(9A)
(Models with manual Free-Flow Tomlinson handles cannot be changed to portion control.)
16) Press (>) for
Sales Mode. (14A)
(
This option for future use. “Free” is currently the default setting.
)
17) Press (>) to retrieve
Sales Data. (15A)
18) Press (>) to view
Total Dispense
data (number of drinks dispensed per head).
(15B)
Press the dispense buttons that you want to retrieve information about.
After viewing each head’s data, proceed to next step.
19) Press (>) to view
Total Brews
data.
(15E)
LCD will display total number of drinks dispensed by the unit.
20) Press (>) for
Clear Data
options.
(16A)
Press (+) or (-) to toggle between YES (resets sales data counter to “0”) and NO.
Important
: After selecting YES and then pressing (>) all data will be cleared immediately.
21) Press (>) to view
Dispenser Type. (17A)
LCD will display type of dispenser.
22) Press (>) to display
Date Code
information.
(18A)
LCD will display manufacture date.
23) Press (>) to display
Software Version
on controller.
(19A)
Displays current software version stored in controller memory.
24) Press (>) to
Retrieve Error Codes. (20A)
Press (+) or (-) to toggle through and review all error codes. The LCD will display the number of times each
error code has occurred. Error Codes:
SC1: No Water Pressure
SC2: Reset Power (Error has occurred that requires power to be reset).
SC3: Low Water Level (Inlet valve ON for more than 5 minutes.)