![Grindex MASTER H Installation, Care And Maintenance Download Page 16](http://html.mh-extra.com/html/grindex/master-h/master-h_installation-care-and-maintenance_2265333016.webp)
Installation, care and maintenance
MASTER
16
Recommended inspections:
Inspection of
Action
Make sure that the cable clamps are tight. If the cable entry leaks:
— check that the entry is irmly tightened into its bottom-most position.
— cut a piece of the cable off so that the seal sleeve closes around a
new position on the cable.
— replace the seal sleeve.
— check that the seal sleeve and the washers conform to the outside
diameter of the cables.
Replace the cable if the outer jacket is damaged. Make sure that the
cable do not have any sharp bends and are not pinched.
If faulty, contact an electrician.
Repair faults and notify supervisor of any faults or defects.
Contact a Grindex service shop.
Cables
Starter equipment
Pipes, valves and other
peripheral equipment
Insulation resistance in
the stator
Cable entry