Product description
Applications
Minor
and
Major
are intended to be used for:
— pumping of water which may contain abrasive
particles.
The pumps are available in the following ver
sions:
N
= Normal head version
H
= High head version
Liquid temperature: standard version, max.
40°C (104°F).
Liquid density: max. 1100 kg/m
3
(9.2 lb per US
gal.).
The pumped liquid may contain particles up to
a size which corresponds to the openings in the
strainer. See drawing.
The pH of the pumped liquid: 5 – 8.
Depth of immersion: max. 20 m (65 ft).
For other applications contact your nearest
Grindex representative for information.
WARNING!
The pump may not be used
in an explosive or flammable
environment or for pumping
flammable liquids.
WARNING!
If the pump run dry or snore,
the pump surface and the sur-
rounding liquid may be hot.
Bear in mind the risk of burn
injuries.
WARNING!
The machine is not to be
installed in locations classified
as hazardous in accordance
with the national electric code,
ANSI/NFPA 70-1990