. Liquid Propane Tank Installation
From rear of grill place the liquid propane
tank into the Bottom Panel (B) hole
and tighten the Tank Bolt (EE)
to secure. As shown in Fig.22.
19.
Liquid Propane Hook-Up
Attach the regulator to the propane cylinder by
turning the regulator handle clockwise as shown
in Fig. 23. If the outdoor cooking appliance is not
in use, the gas must be turned “OFF” at the Liquid
Propane Cylinder.
Check all gas supply fittings for leaks before
each use. Do not use the grill until all connections
have been checked and do not leak
(see “Leak Testing”
instructions on page 17).
INSTALLATION INSTRUCTIONS
GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be specified by the grill manufacturer.
This grill is configured for Liquid Propane. Do not use a Natural Gas supply.
Total gas consumption (per hour) with all burners set on “HI”:
Main burners 48,000 BTU/Hr.
Side burner
12,000 BTU/Hr.
Total
60,000 BTU/Hr.
The installation of this appliance must conform with local codes or, in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA
B149.2.
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for
gas burning appliances and equipment) and local codes.
Fig. 23
Propane Cylinder
Regulator
Fig. 22
Tank Bolt
R
80 0
70 0
6 00
50 0
40 0
300
2 00
10 0
Always keep the LP cylinder at
90° (upright) orientation to
provide vapor withdraw.