9
INSTALLATION CONTINUED
INSTALLATION S-DRIVE
Connection
The PRIMARY Entrapment Protection Device MUST be installed on the main control board
Control Board:
CLOSE EYES (Infrared Safety Beams)
The CLOSE EYES/INTERRUPT input is for Photoelectric sensor
entrapment protection in the CLOSING direction. When an obstruction
is detected during closing, the door will stop and open to the fully
open position. Timer to close will be reset. This input will be
disregarded during opening.
CLOSE EDGE (Safety or Bump Edge)
The CLOSE EDGE input is for monitored (8K2) contact edge sensor
entrapment protection for the close direction. When an obstruction is
detected during closing, the door will stop and open to the fully open
position. Timer to close will be disabled after a second obstruction is
detected. This input will be disregarded during opening.
OPEN EYES/EDGE
The OPEN EYES/EDGE input is for photoelectric or contact edge
sensor entrapment protection for the open direction. When an
obstruction is detected during opening, the door will stop and travel
down for 2 seconds. This input will be disregarded during closing.
Open Eyes / Edges can be used on doors that may present an
entrapment danger in the opening direction.
TO REMOVE AND ERASE MONITORED ENTRAPMENT
PROTECTION DEVICES
1.Remove the entrapment protection device wires from the terminal
block.
2.Press and release the SET OPEN and SET CLOSE buttons
simultaneously. The SET OPEN and SET CLOSE LEDs will turn on
(entering learn limit mode).
3.Press and release both SET OPEN and SET CLOSE buttons again to
turn off the SET OPEN and SET CLOSE LEDs (exiting learn limit
mode).
EXPANSION BOARD
EYE ONLY and COM Open or Close direction photo electric sensors
with selectable functionality.
EYE/EDGE and COM (x2)
Open or Close direction photo electric sensors OR contact edge
sensors with selectable functionality.
DIP SWITCH SETTINGS
The DIP Switches located next to the terminals have the following
functions.
Set to Close:
The door will stop and reverse to open when an obstruction is
detected.
Set to Open:
The door will stop and retract when an obstruction is detected.