Electrical Installations

Electrical connections may only be carried out by certified electricians

•  Additional national regulations regarding the maintenance and repair of electrical systems shall be observed. These 

may result in an increase in the maintenance intervals.

Operation

Motorized operation

Blinds are operated using central or local wall-mounted or hand-held controls with an Up / Down / Stop button. The operating 

functions of the controls are described in the operating instructions for the controls.

Manual operation

Blinds are operated using an articulated crank.

Use

•  The external venetian blinds meet the requirements of the wind classes indicated in the declaration of conformity and may 

remain extended only up to the specified wind class.

•  External venetian blinds provide solar shading and may not be used as security equipment.
•  When operating the awning manually, stand directly in front of the crank assembly to operate the blind.
•  When operating an external blind, ensure that no obstacles (flower pots, toys, chairs, etc.) are located in the blind’s path.
•  Never lower the blind with the window open (European standards and guidelines).
•  When operating the blind manually, do not use force if the blind jams. Change the direction of rotation in order to check if 

the blind has reached the end of the track.

Maintenance / Inspection

Any repairs must be carried out by a qualified technician. 

Interval

Location

Task

Monthly

Avoid damage to positioning mechanism 

due to harmful environmental influences

•  Move product through complete range, from top to 

bottom, at least once

Several times a year

Guides and slats

•  Check guides
•  Clean (depending on contamination level caused by 

surrounding area and environmental impact)

•  Remove any foreign objects (e.g., leaf debris) 

Cable tension

•  Check cable tension
•  Retension or replace cable  tensioner if necessary

Additives that can be used for maintenance

Alkaline, acidic or abrasive lubricants must not be used.

Resources

Location

Task

Rinse with clear water Entire Product except motor

Cleaning the slats and guides

Grease-free lubri-

cants

Guide

Lubricating the slider and the guide rails

Silicone grease
Dry lubricants
PTFE-based aerosol