<bt address>, <bt name>, <cod>
00A053000123,MySerialPort,72010C
H
Will print out a list of
Help
commands and their basic syntax.
R,1
Forces a complete reboot of the device (similar to a power cycle)
&
-
Returns the value of the switches on BluePort XP, or value of PIO3,4,6,7 on other
modules.
U,<rate>,<E,O,N>
Temporary UART Change, will change the serial parameters immediately, but not store
them. Command will return “AOK” at current settings, then switch to new.
Example: “U,9600,E” Sets baudrate to 9600, parity even.
5.3 Factory Default Power up Settings
•
Bluetooth Service Profile = Serial Port Profile (SPP)
•
Mode = 0 Slave
•
Baud Rate = 115200bps, Parity=None, Data bits = 8 bits(fixed), Stop bits 1 (fixed).
•
Power Mode = Auto low power discoverable mode.
•
Name of Device (local name) = BluePort XP-XXXX last 2 bytes of BT address
•
Service Name = SPP
•
Service Class=0000 (undefined service type)
•
Major & Minor Class Of Device (COD) = 0x1F00 (unknown device type)
•
Authentication Disabled
•
Encryption disabled
•
Discovery Enabled (0x0200 = window, fixed interval of 0x800= 1.28 Seconds)
•
Connection Enabled (0x0200 = window, fixed interval of 0x800= 1.28 Seconds)
•
Bonding Disabled (0)
•
Config Timer=60 seconds
•
SNIFF mode disabled
•
Default PIN = “1234”
Note: Switch 1, Set ON at power up time and then toggled 3 times will change all settings above back to
their factory values (except the Device name). Device will reboot immediately upon detection of this mode.