Maintenance
Grex Tritium Series Owner’s Manual
12
®
5.5 Needle Pumping
With rear handle cap removed, loosen the needle lock.
Partially fill the paint reservoir with water or cleaner.
Hold the needle and move it slightly in and out of your airbrush
repeatedly (pumping) to clean the internal packing. Refer to
Figure 5B on page 11.
Pour out the dirty solution.
Add water or cleaner to the paint reservoir and continue
pumping until the solution in the paint reservoir remains clean.
Carefully slide needle forward into fluid nozzle. Make sure it
sets firmly into the fluid nozzle. Re-tighten needle lock and
replace rear handle cap.
5.6 Airbrush Straight Flushing
Partially fill the paint reservoir with water or cleaner and spray at a
heavy spray setting into a paper towel, waste container or similar
material. Repeat straight flushing your airbrush until the solution
sprays out clean. The internal paint passageway should now be
clean.
5.7 Cleaning Paint Reservoirs
Tritium.TG
- Thoroughly clean the paint passageway at the bottom
of the paint reservoir. Refer to Figure 5C on page 11.
Tritium.TS side cups
- Remove the paint cups and thoroughly clean
the paint passageway through the cup. Remove and clean the lock
nut and also the threads of the cup. Thoroughly clean the opening
on the side of the airbrush. Refer to Figure 5D below.
Tritium.TS AD32 side siphon adaptor
- Remove the adaptor and bottle
cap. Thoroughly clean the adaptor, paint passageway of the
adaptor, bottle, and bottle cap, including the plastic tubing. Refer to
Figure 5E below. Also thoroughly clean the side openings of the
airbrush.
1.
2.
3.
4.
5.
6.
Figure 5E.
Lock Nut
Figure 5D.
Lock Nut