Connection of the cooker with gas-main:
Attention!
Before the connection, check the compliance of local connection terms (type
of gas and gas pressure) of device adjustments, the parameters are indicated on
the label, which is placed on side wall of cookers and can be seen when the door
is opened, also you can find it in the certificate of acceptance of the operation
manual.
The cooker must be mounted only by the specialist, who has the corresponding
authorities.
Use the gas hoses, tubes, seals and other pieces, in accordance the national
standard.
- For connection to the gas-main cooker has screw thread G1/2 and is
completed with seals and filter (net).
- The connection is executed with help of tubes and additional pieces which
correspond to the national standards.
- The length of the gas tube for connection mustn’t exceed 2000 mm.
- When connecting the cooker with balloon with liquefied gas, regulate its pressure in
accordance with existent standards of safety measures.
Attention!
For safe work of the equipment make sure, that gas pressure corresponds to the data,
mentioned in the Table 1 “Characteristics of burners and nozzles”
- Connection by gas hose carried out by means of nipple
Ø
8 mm – for liquefied gas
Ø
13 mm – for nature gas
Besides the following requirement must be fulfilled:
- The hose mustn’t touch the cooker’s part in whole length, the temperature of which
is more than 50°C
- The length of the hose should be no more then 1500 mm.
- The hose mustn’t be stretched and kinked or have curves and cracks
- The hose mustn’t be pressed by anything and mustn’t contact with moving pieces
and with things which have sharp edges
- The hose along the all length must be available for examination and control
• The hose and additive connective pieces should correspond to the local standards
• Check the tightness of the hose hold from both sides and fix it by brackets. If at least
one of conditions is not carried out, use the flexible metalized pipes.
• After the connection you need to check the tightness of all the connections, by using
soap solution. It is forbidden to use the flame for tightness inspection.
Attention! This device mustn’t be connected to the pipe bend of gaseous
wastes. It must be installed and connected in accordance with existing regula-
tions of installation. It is specially important to pay attention of the corresponded
ventilation measures.
Connection of the cooker to the electrical network.
• The cooker is connected to the electrical network with alternate one-phase current
(220-240V~50-60Hz) and equipped with power cord 3x1,5mm
2
with cast contour plug .
• The nominal power of an electrical devices is not more than 3 kWt
• Before the connection make sure in success of power cord, socket.
• The socket must be situated in available place in the distance not more than 1,5m
from the cooker.
• The socket mustn’t be situated under the cooker.
• Never use the stretchers, adapters and double and more sockets, which can serve
as a reason for inflammation and overheating
17
STORAGE RULES
• Before installation the cooker should be stored in the original packing in closed or
other places with natural ventilation without artificial adjustable climatic conditions.
• Warehousing of cookers in the packing should be made no more than in two decks
on height.
• Delivery of cookers to the installation place is made in packing.
• Capture of cookers for the oven door handle and for collector pipe in carrying is
forbidden.
POSSIBLE MALFUNCTIONS AND METHODS OF THEIR
ELIMINATION
The malfunction name,
external visualization,
additional factors
Probable causes
Method of elimination
Highlight of the oven
does not operate
Mains interruption
To check mains. To recover if it is
necessary.
Lamp’s defect
To check operability of the lamp, if it is
necessary to replace for similiar
Indicator of switched on
condition does not work
Mains interruption
To check mains. To recover if it is
necessary.
Indicator’s defect
To check operability of the indicator,
if it is necessary to replace for the
similiar
Ignition does not operate
Mains interruption
To check mains. To recover if it is
necessary.
*Ignition generator is
defective
When damaging to replace for similiar
Gas is not kindling near
the hole of the burner of
the table
Nozzle hole is choked
To clean the hole
Guard device of the table
burner does not actuate
defective thermocouple
*to replace thermocouple
defective safety valve
(electric magnetic plug)
*to replace safety valve
* repair is carried out by specialists of gas institutions and by representatives of service
centersIf, despite recommendations the problem was not eliminated, contact gas service
on abiding place or in the service centre.
WARRANTY
• The warranty period of operation of the cooker is 1 year from the date of sale through
the retail trading system, and in the absence of the mark in operation manual about sale is
from the date of issue by manufacturer.
• The warranty period of storage of the cooker is 12 months from the date of issue by
manufacturer at observance of rules of storage accoding to the present operation manual.
• The warranty does not extend on the cookers used on public catering establish-
ments (cafe, restaurants, etc.) or the general using (offices, etc.).
• The warranty does not extend on the products malfunctions of which are caused
by transport damages, wrong installation, the negligent treatment (cracks, scratches and
others mechanical damages caused in result of operation) or bad maintenance (applica-
tion of abrasive, acid and others facilities which are not recommended for cleaning of
enamel surfaces)
• The Buyer should receive the operation manual for the product with a shop mark