3  Product description 

3.1  Scope of delivery 

GMH 3850 
9V battery type IEC 6F22 
Operating Manual 

3.2  Operating and Maintenance 

1.  Battery Operation 

The battery has been used up and needs to be replaced, 

if “bAt“ is shown in lower display. The 

device will, however, continue operating correctly for a certain time.  
The battery has been completely used up, if ´bAt´ is shown in the upper display. 

2.  The battery has to be removed, when storing device above 50°C. 

 

We recommend to remove the battery if device is not used for a longer period of time!  

            Risk of leakage! 

3.  Treat device and probes carefully. Use only in accordance with above specification. (do not throw, hit 

against etc.). Protect plugs and sockets from soiling. 

4.  Mains Operation 

When using a power supply unit please note that operating voltage has to be 10.5 to 12 V 
DC. Do not apply over voltage!! Simple 12V-power supplies often have excessive no-load 
voltage. We, therefore, recommend using regulated voltage power supplies. Trouble-free 
operation is guaranteed by our power supply GNG10/3000. 
Prior to connecting the plug power supply with the mains supply make sure that the 

operating voltage stated at the power supply is identical to the mains voltage. 

5.  Cable break or  no connected / too dry / highly insulating material: 

 

 

 

There may still corresponding %-values are displayed 
- This shall not constitute a valid test result!

 

 

3.3  Start up and readiness for operation 

After switching on the instrument, a self test is performed (approximately 5 seconds).  
During this time all display segments are shown. 
After this sequence the instrument changes to measuring operation and is ready for use.

 

 

 

Summary of Contents for GMH 3830

Page 1: ...3128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de as of version 2 1 Operating Manual GMH 3830 Resistive material moisture and temperature measuring Instrument keep for future refer...

Page 2: ...G OTHER MATERIALS 8 5 6 1 Hard Materials concrete or similar Measuring with brush type probes GBSL91 or GBSK91 8 5 6 2 Soft Materials polystyrene or similar Measuring with Measuring rods or pins GMS 3...

Page 3: ...n indirect impact on the operation or can trigger an unforeseen reaction if ignored table 1 2 2 Safety Instructions This device has been designed and tested in accordance to the safety regulations for...

Page 4: ...ove specification do not throw hit against etc Protect plugs and sockets from soiling 4 Mains Operation When using a power supply unit please note that operating voltage has to be 10 5 to 12 V DC Do n...

Page 5: ...splay elements 3 Moisture evaluation Evaluation of the material condition via top arrows DRY MEDIUM WET 4 Warning triangle Indicates low battery 5 u or w Displays unit moisture content u or wet basis...

Page 6: ...F All temperature values are in degrees Fahrenheit oFF Atc off temperature input for compensation via keys 5 4 on Atc on temperature compensation via internally measured temperature or external probe...

Page 7: ...re measuring devices use one single group for spruce and oak in reality the deviation of these characteristic curves is more than 3 Base for this statement are complex statistical surveys considered m...

Page 8: ...ure dispersion may be irregular often in the core is more moisture than on the edge Surface moisture The wood edge could be more humid than the core if the wood had been stored outside and e g was in...

Page 9: ...measuring value an individual moisture estimation will be displayed simultaneously This moisture evaluation is only a guidance value the final evaluation is depending on the application of the materi...

Page 10: ...tion x X 0 read nominal value x x 202 read unit of display x X 3 read system status x x 204 read decimal point of display x 12 read ID no x 205 read extended measuring type in display x X 176 read min...

Page 11: ...o valid signal Connect meas material charge at the probe device will discharge esp at dry wood Wait until probe has discharged Sensor broken or device defective return to manufacturer for repair Err 1...

Page 12: ...g Output 3 5mm audio plug stereo Selectable as serial interface via optically isolated interface adapter GRS3100 GRS3105 or USB3100 p r t accessories directly connectable to RS232 or USB interfaces or...

Page 13: ...Japanese Fraxinus mandshurica h 134 4 100 Ash Red Flindersia excelsa h 21 5 86 Ash Scaly Ganophyllum falcatum h 22 5 100 Ash Silver Northern Flindersia schottina h 23 7 89 Ash Silver Queensland Flinde...

Page 14: ...ustralasicum h 113 7 85 Cupiuba Goupia glabra h 147 6 69 Curupix Micropholis h 114 6 63 Cypress Cupressus spp h 456 5 100 Cypress Northern Callitris intratropica h 115 6 100 Cypress Rottnest Island Ca...

Page 15: ...Mahogany White Eucalyptus acmenoides h 247 6 100 Mahogony Khaya Khaya spp h 235 7 100 Mahogony American Swietenia spp h 234 6 100 Mahogony Phillipines Parashorea plicata h 236 5 100 Mahogony Phillipi...

Page 16: ...diata New Zealand sapwood aac Pinus radiata h 338 7 100 Pine Radiata New Zealand sapwood boliden Pinus radiata h 339 6 100 Pine Radiata New Zealand sapwood boron Pinus radiata h 340 6 89 Pine Radiata...

Page 17: ...ilschmiedia tawa h 416 6 77 Tawa sap heart untreated Beilschmiedia tawa h 417 7 82 Teak Tectona grandis h 418 6 100 Terap Artocarpus elasticus h 419 2 100 Terentang Campnosperma brevipetiolata h 420 5...

Page 18: ...KM 1 3 b 14 0 4 40 4 Lime sand bricks 14 DF 200 gross density 1 9 b 28 0 1 12 5 Limestone b 15 0 4 29 5 MDF b 16 3 3 52 1 Cardboard b 17 9 8 100 0 Stone timber b 18 10 5 18 3 Polystyrene b 25 3 9 50...

Reviews: