1.6. Safety guidelines 

1.   Faultless operation and reliability in operation of the measuring device can only be assured if 

the device is used within the climatic conditions specified in the chapter “Specifications“. 

2.   

 

S

ensors are not allowed to used in „under-water-diving-application” (e.g. 

Rebreather)

 

3.   When connecting the device to other devices the interconnection has to be designed most 

thoroughly, as internal connections in third-party devices (e.g. connection of ground with pro-
tective earth) may lead to undesired voltage potentials. 

4.   

 

The device must be switched off and must be marked against using again, in 
case of obvious malfunctions of the device which are e.g.: 
- Visible damage. 
- Device does not work like prescribed. 
- Storing the device under inappropriate conditions for longer time. 
When not sure, the device should be sent to the manufacturer for repairing or 
servicing. 

5.   Modifications or repairs of the device may not be performed by the customer. 

6.   If the device is transported from a cold to a warm environment condensation may result in a 

failure of the device. In such a case make sure the device temperature has adjusted to the 
ambient temperature before trying a new start-up. 

7.   

 

The sensor contains 

KOH

 (GOEL 381) or 

acid

 (GOEL 370). 

KOH and acid can cause severe chemical burns! 
If leaking, avoid contact! 

If there was contact:

 

 

• to skin: Flush contacted area with large amounts of water for several minutes. 

 

• to clothing: remove contaminated clothing. 

 

• to eyes: Flush with large amounts of water for several minutes, obtain medical 

treatment. 

After swallowing:

 

 

• give large volumes of water. DO NOT induce vomiting! 

 

• Obtain medical treatment

 

2. Product description 

2.1. Scope of supply 

  Oxygen sensor in housing 

  Operating manual 

2.2. General information about application areas 

GOEL 370 (acidic electrolyte):  

Integrated in GGO 370, GGA 370, GOO 370 (for GMH 3690/-91/-92/-95) 

Or in GGO 570, GGA 570, GOO 570 (for GMH 5690/-95)

 

Specialized sensor for diving application e.g. measuring Nitrox. Construction is optimized to this 
application. Also suitable to measure oxygen-concentration in air or other gases with a high CO

2

-

concentrations or even in a CO

2

-atmosphere. Application above 35 Vol. % O

2

 has reduced preci-

sion. The acid electrolyte guarantees that the sensor could not be influenced by CO

2

 

GOEL 381 (basic electrolyte):  

Integrated in GGO 380, GGA 380, GOO 380 (for GMH 3690/-91/-92/-95) 
Or in GGO 580, GGA 580, GOO 580 (for GMH 5690/-95 
Sensor for

 low oxygen concentration

 e.g. controlled atmosphere. Without larger CO

2

 concentration*) 

 

 

Summary of Contents for GGO Series

Page 1: ...NY 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Operating Manual Oxygen partial pressure sensor in specialized housing GGO GGA GOO GOG ResOx Please read these instructions carefully before us...

Page 2: ...ly read and understood this manual before starting any work The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one ignoring advices of this manu...

Page 3: ...age to the device or environment at non observance Note This symbol point out processes which can indirectly influence operation pos sibly cause incorrect measurement or provoke unforeseen reactions a...

Page 4: ...has adjusted to the ambient temperature before trying a new start up 7 The sensor contains KOH GOEL 381 or acid GOEL 370 KOH and acid can cause severe chemical burns If leaking avoid contact If there...

Page 5: ...are available which happens normally at the end of life time The nominal life time can be shortened significantly by usage Influencing factors are Storage Operation temperature Humidity of measured ga...

Page 6: ...th pressure connection If You use an instrument with pressure connection e g GMH 3695 this type is optimal Especially at systems with over or under pressure or at dy namic pressure due to gas flow It...

Page 7: ...crew in sensor 3 in part 1 Do not forget O Ring 2 Unscrew the sensor carefully e g by means of suitable nippers The audio plug of part 4 has to be connected to the socket in the sensor If this makes p...

Page 8: ...rolyte basic acidic Connection approx 1 m cable Temperature sensor integrated Storage temperature 15 to 60 C Operating ambient 0 45 C 0 50 C Ambient pressure 0 6 1 75 bar abs 0 5 to 2 0 bar abs Over u...

Reviews: