11 | Spare parts and accessories

32 / 35

B-H86.0.12.DB2-1.0

11 Spare parts and accessories

A selection of spare parts and accessories for this product is listed below.

Article

Number

Name

Description

610049

Mignon battery
AA

Mignon AA spare battery

603523

GAK 1400

Working and calibration set

600704

GE 100

Universal pH electrode with BNC connection

600693

GE 101

Ø 0.6 mm tip pH electrode with BNC connection

602063

GE 104

pH electrode for low-ionic media with BNC connection

600713

GE 108

Low-maintenance pH electrode with BNC connection

606089

GE 108

Low-maintenance pH electrode with S7 connection

604701

GE 114

Affordable, low-maintenance pH electrode with BNC
connection

600730

GE 117

Temperature-compensated pH electrode with BNC con-
nection

600698

GE 120

Ø 13 mm insertion pH electrode with BNC connection

600732

GE 125

Immersible, waterproof pH electrode with BNC connec-
tion

600727

GE 151

Chemically-resistant pH electrode with BNC connection

606375

GE 171

Sterilisable pH electrode for extreme conditions with S7
connection

600735

GE 173

Alkali-resistant pH electrode with BNC connection

606572

GE 173

Alkali-resistant pH electrode with S7 connection

601996

GEAK-2S7-
BNC

Adapter cable S7-BNC, 2 m

601998

GEAK-2S7-
BNC

Adapter cable S7-BNC, 5 m

601060

GKK 1100

Case with nap foam, 340 x 275 x 83 mm

601056

GKK 252

Case with nap foam, 235 x 185 x 48 mm

601417

GPF 100

Plastic bottle with wide neck, 100 ml

602619

GPH 10.0 / 10

10 buffer capsules, pH 10.0

602618

GPH 10.0 / 5

5 buffer capsules, pH 10.0

602621

GPH 12.0 / 10

10 buffer capsules, pH 12.0

602620

GPH 12.0 / 5

5 buffer capsules, pH 12.0

602615

GPH 4.0 / 10

10 buffer capsules, pH 4.0

602614

GPH 4.0 / 5

5 buffer capsules, pH 4.0

602617

GPH 7.0 / 10

10 buffer capsules, pH 7.0

602616

GPH 7.0 / 5

5 buffer capsules, pH 7.0

607798

GR 105

Redox electrode with BNC connection

607801

GR 175

Redox electrode with BNC connection

607802

GR 175

Redox electrode with S7 connection

601422

GRL 100

Pepsin cleaning solution, 100 ml

602914

GWA1Z

Threaded adapter PG13.5 to G1

602477

KCL 3 M

3 mol KCL electrolyte for refilling, 100 ml

603205

PG 13.5

Plug-in thread adapter for pressureless insertion of all
electrodes

601373

PHL 10

Ready-to-use buffer solution, pH 10.01 / 25 °C, 250 ml

601370

PHL 4

Ready-to-use buffer solution, pH 4.01 / 25 °C, 250 ml

Summary of Contents for G 1501

Page 1: ...Operating manual EN...

Page 2: ...nce 10 4 1 The G 1501 10 4 2 Display elements 10 4 3 Operating elements 10 4 4 Connections 11 5 Bases for measurement 12 5 1 pH measurement 12 5 1 1 Explanation 12 5 1 2 pH electrode 12 5 1 3 Design 1...

Page 3: ...Configuring parameters of the configuration menu 24 7 2 4 Adjustment of the measuring input 26 7 2 5 Configuring parameters of the adjustment menu 27 8 Error and system messages 28 9 Disposal 30 10 T...

Page 4: ...l notices The liability and warranty of the manufacturer for damages and consequential dam ages are voided with misuse disregarding this operating manual disregarding safety notices assignment of inad...

Page 5: ...t Outcome of an action Result consequence or effect of an instruction Emphases In order to simplify legibility and provide a clearer overview various sections informa tion are emphasised 1234 Display...

Page 6: ...l indicates processes which can have a direct influence on operation or can trigger an unforeseen reaction in case of non observance NOTE This symbol instructs the use of eye protection which protects...

Page 7: ...easures in samples for measurements in foods Discard these samples after the measurement DANGER Potassium chloride potassium nitrate The electrode contains potassium chloride or potassium nitrate All...

Page 8: ...e for example drinking water waste water surface water swimming pools fish breeding and process chemistry See Technical data p 31 2 5 Qualified personnel For commissioning operation and maintenance th...

Page 9: ...d reliability in a compact ergonomic housing Additional impressive features include the dust proof and waterproof design in accord ance with IP 65 67 and the 3 line illuminated display which offers ov...

Page 10: ...e for min max hold Auxiliary display Corresponding temperature for the displayed pH value with unit Measured temperatures are dis played with a decimal place adjusted without Bar graph Progress for ca...

Page 11: ...NF appears in the dis play Long press 4s Start automatic calibration AL appears in the dis play 4 4 Connections BNC connection Connection for electrode Un locking with rotating ring on the cable plug...

Page 12: ...ion it should always be recorded together with the measurement temperature because most liquids change their pH value with the temperature The following must be observed avoid interference electrostat...

Page 13: ...can result in blockage of the diaphragm In solutions that contain proteins such as for measurements in medical and biolo gical applications KCl can cause denaturation of the protein Coagulated paints...

Page 14: ...care and maintenance of the electrode Normal cleaning takes place with the GRL 100 pepsin cleaning solution into which the electrode is immersed for 5 minutes before being rinsed off with clean water...

Page 15: ...ithin a specific Redox range The measure ment is also important in drinking water preparation waste water monitoring and in in dustrial applications Measurement takes place relative to the widespread...

Page 16: ...mperature range is exceeded or undercut the electrode can be destroyed It should always be stored wet in 3 mol l KCl Extended storage in distilled or deionised water will result in depletion of the re...

Page 17: ...g handling instructions before replacing batteries and follow them step by step If disregarded the product could be damaged or the protection from moisture could be diminished Description Proceed as f...

Page 18: ...ct To achieve a precise measurement observe the following points NOTE If possible the calibration range should overlap the measuring range To achieve this it is recommended to use buffer solutions for...

Page 19: ...that nothing is spilled They can also be used without opening them opening the capsules only reduces to time for dissolving 3 Place the buffer capsule and its contents in the plastic bottle 4 Wait at...

Page 20: ...appears in the display See Error and system messages p 28 Confirm the error message pressing the Function key The product restarts and the standard value for the zero point and gradient are restored...

Page 21: ...with a value between pH 6 75 and pH 7 25 7 Wait until the display value is stable 8 Adjust the value corresponding to the buffer solution with the Up key and Down key and confirm the entry by pressin...

Page 22: ...nised worldwide These certificates offer high quality calibration and consistently high quality DAkkS calibration certificates can only be issued by accredited calibration laboratories which have dem...

Page 23: ...product must be calibrated to the electrode prior to starting the measurement If the electrode is chosen re calibration is necessary See Calibration and adjustment service p 22 7 2 Configuration 7 2 1...

Page 24: ...the configuration menu Description The following representation shows the available parameters and various configura tion options Prerequisite The Configuration menu is open See Opening the configurat...

Page 25: ...via text display and flashing of the backlighting AL LO Depending on the setting of the parameter value INP PK 0 00 AL K mV 1500 AL K mVH 1293 AL K AL K Depending on the setting of the parameter valu...

Page 26: ...correc tion is made In order to adjust the product you must first open the Adjustment menu The menu is opened as shown in the illustration Prerequisites Sufficiently full batteries are inserted in the...

Page 27: ...perature T SL 0 00 No gradient correction 5 00 5 00 Gradient correction in Formula Zero point correction Displayed value measured value T OF Gradient correction C Display measured value T OF 1 T SL 10...

Page 28: ...in ated or defective Use fresh buffer solution Clean electrode re calibrate Replace electrode AL ERR 3 Slope is too high Incorrect buffer solu tion used Buffer solution is contaminated Electrode conta...

Page 29: ...Error and system messages 8 B H86 0 12 DB2 1 0 29 35 Replace batteries Send in for repair...

Page 30: ...online at www ghm group de and sent it in with the product NOTE The device must not be disposed of with household waste If the product is disposed of please take it to a municipal collection point whe...

Page 31: ...ght 108 54 28 mm without BNC plug 130 g incl battery without electrode 190 g incl battery and electrode Operating conditions 20 to 50 C 0 to 95 r h temporarily 100 r h Storage temperature 20 to 70 C C...

Page 32: ...35 GE 173 Alkali resistant pH electrode with BNC connection 606572 GE 173 Alkali resistant pH electrode with S7 connection 601996 GEAK 2S7 BNC Adapter cable S7 BNC 2 m 601998 GEAK 2S7 BNC Adapter cabl...

Page 33: ...ion pH 7 00 25 C 250 ml 611373 ST G1000 Device protection bag with 1 round cut out A complete list of all accessories and spare parts is available in our product catalogue or on our home page We can a...

Page 34: ...r de WEEE reg no DE 93889386 12 2 Repairs Defective products are repaired professionally and quickly in our service centre Open hours and contact Monday to Thursday from 8 00 to 16 00 Friday from 8 00...

Page 35: ...rance SAS Parc des Pivolles 9 Rue de Catalogne 69150 D cines Charpieu Lyon FRANCE Phone 33 4 72 37 45 30 a jouanilou ghm group fr India GHM Messtechnik India Pvt Ltd 209 Udyog Bhavan Sonowala Road Gre...

Reviews: