background image

GREER COMPANY 

Crane Systems 

 

 

THE BA-

151

0

™ 

ANGLE IN

DICAT

OR (METER) 

The BA-

1510™ Angle Indicator (meter) is used during setup and operation of the 

crane to display the crane boom angle and to set and display crane boom minimum 

and maximum angle limits. The System provides visual and audible warning alerts if 

the set limit(s) are exceeded. Motion cuts (halting of crane hoist up, extend out, and 

boom down movements) are available as an additional option, if desired. (Refer to 

MOTION CUTS, page 7.) 

SETTING AN ANGLE LIMIT 

Position the crane boom at the desired limit. 

Refer to the illustration on the opposite page while following the steps below. 

 

1. 

PRESS SET MIN 

OR 

SET MAX. 

 

2. 

PRESS 

THE 

UP 

or 

DOWN ARROW 

IN THE CENTER OF THE METER TO 

ADJUST THE LIMIT. 

 

3. 

PRESS ENTER. 

NOTE

: The alarm(s) will activate until the boom is withdrawn from the SET 

limit SHOWN on the display. 

 

REMOVING AN ANGLE LIMIT 

1. 

PRESS SET MIN 

OR 

SET MAX. 

 

2. 

PRESS CANCEL 

NOTE: 

The limit will be replaced with a dashed 

– – – – – line. 

Summary of Contents for Crane Systems BA 1510

Page 1: ...GREER COMPANY Crane Systems BA 1510 ANGLE INDICATOR OPERATOR S MANUAL HYDRAULIC LATTICE CRANES...

Page 2: ...ienced crane operator in safe crane setup and operation involving boom angles This manual provides the operator with instructions for using the BA 1510 System At no time may this System be used as a s...

Page 3: ...ANUAL HYDRAULIC LATTICE CRANES BA 1510 ANGLE INDICATOR 5 SETTING AN ANGLE LIMIT LIMIT 5 REMOVING AN ANGLE LIMIT 5 THE ALARMS 6 PRE ALARMS 6 ALARMS 6 MOTION CUTS 7 SPECIAL FUNCTIONS 8 FACTORY RECOMMEND...

Page 4: ...maximum limit Range 9 9 to 99 9 press to set cancel limits yellow and red warning lamps angle of crane boom press to lighten darken display The BA 1510 Angle Indicator meter BA 1510 Operator s Manual...

Page 5: ...nd boom down movements are available as an additional option if desired Refer to MOTION CUTS page 7 SETTING AN ANGLE LIMIT Position the crane boom at the desired limit Refer to the illustration on the...

Page 6: ...nds both the red and yellow lamps light up and a warning message appears Motion cuts if installed will activate OPTIONS WHEN AN ALARM ACTIVATES MOVE OUT OF THE ALARM CONDITION PRESS CANCEL ALARM TO SI...

Page 7: ...ST UP BOOM DOWN AND TELESCOPE OUT BOOM ACTION DURING A TWO BLOCK CONDITION ACTIVATION OF THE MIN ANGLE ALARM HALTS BOOM DOWN UNLESS THE ALARM WAS PURCHASED AS AUDIOVISUAL ALARMS ONLY ACTIVATION OF THE...

Page 8: ...ABLED WHEN THE RIGGING MODE IS ACTIVE PRESS CANCEL ALARM TO EXIT THE RIGGING MODE NOTE THIS ACTION WILL RESTORE ALARMS AND MOTION CUT FEATURES IF INSTALLED CALIBRATION MODE TO ACCESS THE CALIBRATION M...

Page 9: ...LLED 2 IF USING AN ANTI TWO BLOCK SYSTEM TEST THE SYSTEM BY CAUTIOUSLY HOISTING THE HOOK S TO ACTUATE THE SWITCH AND ALARM 3 CHECK THE METER FOR ANY VISIBLE MOISTURE AND KEEP IT AS DRY AS POSSIBLE MON...

Page 10: ...ALLY OR EVERY 1000 HOURS OF OPERATION 1 UNDO THE CABLE CONNECTORS IN THE SYSTEM INSPECT AND CLEAN THESE CONNECTORS GENEROUSLY REPACK EACH CONNECTOR WITH DOW CORNING 111 SILICON GREASE OR A COMPARABLE...

Page 11: ......

Page 12: ...12...

Reviews: