GreenTech RD2690 Series Programming Menu Manual Download Page 1

       

 

 

 

 

Intelligent Radar Level

 

Transmitter

   

Programming Menu

-

RD2690, RD6850 series

 

 

 

Greentech, Korea 

 

www.greentechkor.com                                                                                                                                                    E-mail: [email protected] 

Programming Menu 

RD2690, RD6850 series 

 
 
 
 

Brief Introduction :

 

 

Shown as the figure right, there are four buttons in the indication 
face board, by pressing which, you can set and debug the 
instrument. Menu languages are selectable. After setting or 
calibration, LCD indicates measured values, which can be read 
clearly through a glass window. 

 

Following bellows are functions of the four buttons:   

 
 
 
 
 
 

Button :

 

“ OK ” 

 

Enter editing state 
Confirm settings 
Parameter modification saves 

 

 

“ 

 

” 

 

 

 

Selecting a setting item 
Selecting digits of edited parameters 
Indicating the content of the selected parameter 
Note: hereinafter the button is called as 
“KEY SELECTION” for easy-understanding. 

“ 

+

 

 

Amending values of parameters 
Selecting model of indication 

“ Esc ” 

 

 

Exit from editing state 
Returning back to the previous menu 
Shifting between measured values and chart of 
echoes during operation 

 
 

 

Interpretation of terms : 

Programming interpretation:    Using the four buttons at the indication board can perform 
parameters setting, debugging and test, etc. 
Structure of programming menu: For the structure of menu, please refer to the attached table one. 
The movement of the horizontal arrows to right can be done by button 

“OK”

.     

The movement of the vertical arrow downwards can be performed by button 

“SELECTION”

.   

Button 

“Esc”

   

for the movement to left for the horizontal arrow. 

 

Summary of Contents for RD2690 Series

Page 1: ...Selecting digits of edited parameters Indicating the content of the selected parameter Note hereinafter the button is called as KEY SELECTION for easy understanding Amending values of parameters Sele...

Page 2: ...button to enter programming state display programming main menu Each parameter editor to finish with OK button confirmation otherwise the editor is invalid When done editing press the Esc key to exit...

Page 3: ...ment High position adjustment is for measuring range setting It determines the proportion of output current linearity corresponding relationship together with low position adjustment When LCD indicate...

Page 4: ...ST WAVE AMPLITUDE DEFAULT WEAKEN THE FIRST WAVE AMPLITUDE WEAKEN 10dB LITTLE STRONGER THE FIRST WAVE STRENGTHEN 10dB STRONGER THE FIRST WAVE STRENGTHEN 20dB STRONGEST THE FIRST WAVE STRENGTHEN 40db 1...

Page 5: ...liquid DK adjustment menu LCD indicates as follows DK VALUE SMALL 1 3 5 YES NO Press button SELECTION to select YES and set the measurement when DK value is small LCD indicates as follow then input a...

Page 6: ...easurement result 1 4 Damping time Damping time When LCD indicates the menu number 1 3 press button SELECTION enter damping time setting menu LCD indicates as follows DAMPING TIME 1 4 6S Press button...

Page 7: ...be set When LCD indicates the menu number 1 7 press button SELECTION to enter measuring range setting menu LCD indicates as follows MEASURING RANGE SETTING 1 8 00 000m d Press button OK the correspond...

Page 8: ...er editing press button ESC exit indication programming and go back to the previous menu 2 2 LCD contrast adjustment When LCD indicates the menu number 2 1 press button SELECTION to enter LCD contrast...

Page 9: ...tes graph press button OK to enter curve zoom editing menu LCD indicates as follows CURVE ZOOM 3 4 ZOOM ALONG AXIS X ZOOM ALONG AXIX Y NO ZOOM Press button SELECTION to move the arrow for selecting zo...

Page 10: ...use the function of false echo setting to overcome its interference When LCD indicates the main menu and the menu number is 4 press button OK to enter service submenu LCD indicates as follows FALSE EC...

Page 11: ...e ECHO GRAPH after the modification this time for reference And then press button ESC LCD goes back to the edition interface for further edition When the false echo edition reach to the request of the...

Page 12: ...tting according to the needs 4 4 Measuring unit There are two choices of measuring units for users one is the metric system the other is imperial system When LCD indicates menu number 4 3 press button...

Page 13: ...n SELECTION to select the menu you need and press button OK for confirmation and perform the function 4 8 Password Password is used for the safety of the parameters Once the function is actuated you h...

Page 14: ...pper corner of the screen 3 Press button OK for confirmation Enter the diagnosis submenu 3 1 for indicating measurement peak minimum distance and maximum distance 4 Press button SELECTION to next prog...

Page 15: ...15 Intelligent Radar Level Transmitter Programming Menu RD2690 RD6850 series Greentech Korea www greentechkor com E mail info greentechkor com Attached Diagram...

Page 16: ...16 Intelligent Radar Level Transmitter Programming Menu RD2690 RD6850 series Greentech Korea www greentechkor com E mail info greentechkor com...

Reviews: