GreenTec Warranty 

 

Greentec warrants that the Greentec machine referred to in the Warranty Registration Form will be free from 
defects in materials and workmanship for a period of 12 months from the date of sale.  This warranty does not 
affect your statutory rights, but merely adds to them.  Should you have a problem within 12 months from the 
date of sale please contact your original Greentec dealer, or Greentec’s Service Department.  Any part found to 
be defective during this period will be replaced or repaired, at Greentec’s discretion, by the dealer or a Greentec 
Service Engineer. 

 

Greentec Warranty Conditions

 

 
1.  The Warranty Registration Form (green page) must be completed and returned to Greentec within 7 days of 

the date of sale 
 

2.  This warranty does not cover defects arising from fair wear and tear, willful damage, negligence, misuse, 

abnormal working conditions, use in competition, failure to follow Greentec’s instructions (oral or written, 
including all instructions and recommendation made in the Operator’s Manual) or alteration or repair of the 
machinery without Greentec’s approval. 
 

3.  The machinery must have been serviced in accordance with the Operator’s Manual and the Service Log 

must have been kept up to date and made available to the dealer should service, repair or warranty work be 
undertaken. 
 

4.  This warranty does not cover claims in respect of wearing parts such as blades, flails, paintwork, tires, belts, 

hydraulic hoses, bearings, bushes, linkage pins, top links, ball ends unless there is a manufacturing or 
material defect or the cost of normal servicing items such as oils and lubricants. 
 

5.  This warranty does not cover any expenses or losses incurred whilst the machinery is out of use for 

warranty repairs or parts replacement. 
 

6.  This warranty does not extend to parts, materials or equipment not manufactured by Greentec, for which the 

Buyer shall only be entitled to the benefit of any such warranty or guarantee given by the manufacturer to 
Greentec. Only genuine Greentec replacement parts will be allowable for warranty claims. 
 

7.  All parts replaced by Greentec under warranty become the property of Greentec and must be returned to 

Greentec if Greentec so request.  Such parts may only be disposed of after a warranty claim has been 
accepted and processed by Greentec. 
 

8.  Greentec is not liable under this warranty for any repairs carried out without Greentec’s written consent or 

without Greentec being afforded a reasonable opportunity to inspect the machinery the subject of the 
warranty claim. Greentec’s written consent must, therefore, be obtained before any repairs are carried out 
or parts replaced.  Use of non- Greentec parts automatically invalidates the Greentec Warranty. Failed 
components must not be dismantled except as specifically authorized by Greentec and dismantling of any 
components without authorization from Greentec will invalidate this warranty. 
 

9.  All warranty claims must be submitted to Greentec on Greentec Warranty Claim Forms within 30 days of 

completion of warranty work. 

 

Using the machine implies the knowledge and acceptance of these instructions and the 

limitations contained in this Manual.

 

 

Summary of Contents for HXF 2800

Page 1: ......

Page 2: ...ok different to the machine it relates to please contact the After Sales Department for advice Greentec Machinery Limited 2015 Please ensure that this manual is handed to the operator before using the...

Page 3: ...itional Safety Advice 13 Specifications 14 Before starting work 14 Setting to work position 14 Tool start 15 Tool stop 15 Overhead power lines 16 Assembly Disassembly 16 Transport position 17 Working...

Page 4: ...www greentec eu where the login via the dealer s access gives you the latest updates on instructional and part books on our entire product range The password for dealer log in PUBLISHER We hope you w...

Page 5: ...fully understands the manual s contents If the machine is resold the manual must be transferred to the new owner Please fill out the list below to ensure that the necessary information is at hand whe...

Page 6: ...ation which could result in damage to the machine and or equipment if not observed carefully NOTICE Specific or general information considered important or useful to emphasise LEFT HAND LH RIGHT HAND...

Page 7: ...our execution thereof the item of machinery described below complies with the basic health and safety regulations of the respective EU Directives Product GreenTec HXF 2802 AHS Product code 9992800 Se...

Page 8: ...third party equipment to a vehicle that the maximum possible stability of the machine and vehicle combination is achieved this can be accomplished by the utilisation of ballast in order to counter ba...

Page 9: ...ing the location of the weights to ensure they are added to a position that offers the greatest advantage Front axle locking check with tractor manufacturer NOTE The advice above is offered as a guide...

Page 10: ...gine is running Warning Stay clear of mower sawblades when running Never remove the safety protection Warning Stay out of gears swing area Warning Shut off engine and remove key before performing main...

Page 11: ...000 volt cables is 5 2 meters from the ground When fully extended the machine may well exceed this height so extreme caution should be practiced For more information contact the Health and Safety Exec...

Page 12: ...ound the machine at any time Never attempt any maintenance or adjustment without first disengaging the PTO lowering the head to the ground stopping the tractor engine and applying the tractor parking...

Page 13: ...For 1 km or appropriate shorter distance may be added to the plate Road narrows warning signs with supplementary Single file traffic plate White on blue Keep left arrow sign on rear of machine Note th...

Page 14: ...armsystem Before starting work Setting to work position Remove transport bolt and turn the arm to working position Mount the bolt in the ram Start the tool by low oil flow Low rpm Adjust the HFX 2802...

Page 15: ...nk and can only be adjusted when the machine is stopped A hydraulically ram option can be mounted Operate the ram in the required direction to set the desired cutting angle before starting work The ra...

Page 16: ...the electricity poles there is always a risk of touching overhead lines If in doubt contact the local power station for instructions on safety distance 1 Drive forward Tip the holder on arm 90 2 Tigh...

Page 17: ...HXF 2800 2802 AHS 17 Transport position Remove the bolt Turn the arm 180 Working position Mount the bolt to the ram...

Page 18: ...l grease points until fresh grease shows It is important where possible to store under cover to protect against rain and sunlight Always ensure a firm level surface Control levers must be wrapped in p...

Page 19: ...begin to work Correction is also possible while working Use small movements Large corrections is best done while stationary Control panel 1 Switch on off 2 Cutting angle 3 Tool on off 4 Fuse in the p...

Page 20: ...HXF 2800 2802 AHS 20 Diagrams Splitter Valve...

Page 21: ...HXF 2800 2802 AHS 21 Electric diagram...

Page 22: ...gshane Absperrhahn Cut off valve 3 Manometer Mini mesh 4 Akkumulator 32 bar Dr ckspeicher 32 bar Accumulator 32 bar 5 P k rselscylinder Anfahrsicherungs Zylinder Break back ram Twiga HXF 3300 P k rsel...

Page 23: ...ses quote number stamped on fitting at one end The GreenTec hydraulic system works at very high pressure when replacing hoses use only genuine hoses a burst hose could be very dangerous When replacing...

Page 24: ...Regularly servicing the filtration system Never allowing oil level to fall below the sight gauge Daily inspect all hydraulic connections and fittings to be in good order Any damage or leaks must be re...

Page 25: ...void any discolouring or damage to paint Grease all grease points until fresh grease shows It is important where possible to store under cover to protect against rain and sunlight Always ensure a firm...

Page 26: ...r Reduce operating speed Electrical failure Wrong supply from tractor Check the security fuse and connections from your tractor telehandler Contacts have been exposed to water The machine should be st...

Page 27: ...e pins top links ball ends unless there is a manufacturing or material defect or the cost of normal servicing items such as oils and lubricants 5 This warranty does not cover any expenses or losses in...