TC1S Test Unit Kit
Setup
TC1S Test Unit Kit Components
50065726
TC1S Digital Indicator
50065734
TCC115S AC/DC Adapter/Charger (115 V)
50013424
Carrying Case
Force-sensing Accessories
50065742
TF70(S) Force Sensor (with or w/o ISDS)
max. 70 kN (7.7 tons)
50065750
TF130(S) Force Sensor (with or w/o ISDS)
max. 130 kN (14.6 tons)
50117980
MA50 Adapter for 1.5-ton tools
(used with TF70)
50108557
MA4 Adapter for 4-ton tools
(used with TF70)
50116614
MAMAP1 Adapter for 5-ton tools
(used with TF70)
50065769
MA22 Adapter for 6-ton tools
(used with TF70)
50065777
MA120 Adapter for 12-ton tools
(used with TF130)
50013416
MAVP Adapter for quad-point tools
(used with TF70)
52024054
MA12ID Adapter for 12ID indenter-type tools
(used with TF130)
Charging Instructions
1.
Charge the TC1S for 14 to 16 hours before using the
tool for the first time.
2.
Use only the TCC115S adapter/charger for the
TC1S.
Initialization Instructions
1.
Press
ON
.
2.
During the first 3 seconds of initialization, press
P
,
then
F
, and then
. Press
Prog/Enter
to initialize or
Clear
to continue.
3.
To set language, press
SI/US
and use to toggle
between “units” and “language”. Press
Prog/Enter
to complete the selection.
4.
To set units, press
SI/US
and use to toggle
between “units” and “language”. Select “SI/US” and
press
Prog/Enter
. Use to toggle between “SI” and
“US” units, and press
Prog/Enter
to complete the
selection.
5.
To set date and time, press
Prog/Enter
and
Output
.
Use to select “date” or “time”. Use
and
Prog/Enter
to adjust time and date.
Assembly Instructions
1.
Select the proper force sensor and adapter accord-
ing to the tool output force.
2.
Connect the force sensor interface cable into the
upper right jack of the TC1S Digital Indicator
(marked “F” on back of unit).
Select Force Sensor Value
1.
Turn on the TC1S Digital Indicator.
2.
Press
Prog/Enter
, and then press
F
.
3.
Use to select “*calibr.value”, and then press
Prog/Enter
.
4.
Use
to position the cursor, and to change the
value.
5.
Set value to “70.0 kN” for the TF70(S) and “130.0
kN” for the TF130(S), and then press
Prog/Enter
.
6.
The upper left corner of the TC1S display will
indicate “TF70S” or “TF130S”.
Zero Point Correction
1.
Be sure the load cell is not installed in the adapter.
2.
Turn on the TC1S Digital Indicator.
3.
Press
Prog/Enter
, and then press
F
.
4.
Use to select “set to zero”.
5.
Press
Prog/Enter
twice.
Pressure
Transducer
Computer
Port
Load
Cell
Charger
Port