background image

Greenlee Textron / Subsidiary of Textron Inc.

5

4455 Boeing Dr., Rockford, IL 61109-2988   815/397-7070

1721-m4 Spec. Hydraulic Power Pump

Pump Specifications

PUMP

CONTROL

CONTROL

RESERVOIR

USABLE

APPROX.

MODEL

NO.

VALVE

HEIGHT

BASE

CAPACITY

OIL VOL.

WT.

QT.

501.8479.2 1770/1-7273

AC

1 (15 min.)

115/230

150

30

18.18

10

1

/

2

 x 12

8 qts.

6-1/4 qts.

100

POWER SOURCE

TYPE

HP

VOLTS

100 PSI

10,000 PSI

PUMPING CAPACITY

CU. IN./MIN.

1721-M4

Spec. #60

Never use synthetic fluids or fluids with poor
lubricating qualities, i.e., brake fluids, etc., as
permanent injury to the pump will result.

Eight quarts are required of which 6-1/4 quarts are
usable. A minimum of 1-3/4 quarts must be at the
bottom of the reservoir at all times during operation.
Be sure that your complete operation does not require
more than the usable amount of oil.

To refill or add oil to the reservoir, proceed as follows:

1.

Remove vent unit from top of reservoir.

2.

Add oil to within 1/2" of top of reservoir when ram is
retracted.

3.

Install vent unit securely in place.

Check to see that vent unit is not clogged before
attempting to operate pump.

Draining Oil Reservoir. Unscrew and remove 3/8 inch
pipe plug (68) from side of pump base. Turn pump on its
side to drain all oil from reservoir. Be sure to replace
plug before refilling reservoir with oil.

Servicing Instructions

Filling Oil Reservoir. The oil reservoir must be kept
filled with a good grade of light hydraulic oil.

Flushing System. As long as these pumps are used as
outlined in the operating instructions, long, trouble-free
performance can be expected. To maintain this perform-
ance, it is absolutely essential that dirt or other foreign
matter be kept out of the system as this is the most
common cause of hydraulic system failure. Therefore,
when opening up the pump for any reason, such as
making pipe connections, adjusting pressure or any
repair, be sure to exercise extreme care in cleanliness
and to use clean tools and cloths. If, at any time, dirt is
suspected to have found its way into the system, the
entire oil system should be flushed as follows:

1.

Drain oil from reservoir.

2.

Fill reservoir with any recommended flushing oil or
clean kerosene and operate pump. Work the control
handle back and forth several times during flushing
to wash all foreign particles from the control valve
unit.

Note: Do not operate pump for a very long time as

system is not designed to operate with flushing
oil or kerosene.

3.

Drain flushing oil or kerosene from reservoir and
refill with new oil.

Motor Maintenance

The 1721-M4 Spec. No. 60 pump motor, when in need
of repairs, should be repaired by the manufacturer of
the motor or at one of the qualified GE Service Stations.

Summary of Contents for Soiltest 1721-M4

Page 1: ...reenlee Textron IM 842 REV 6 6 97 HYDRAULIC POWER PUMP 1721 m4 Spec 60 Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this t...

Page 2: ...an be preloaded as rapidly as desired The control valve has a flow adjustment from 3 cubic inches per minute to 500 cubic inches per minute and can be easily adjusted by turning the micrometer adjusti...

Page 3: ...h If injured seek medical help immediately to remove oil Do not use fingers or hands to check for leaks Depressurize hydraulic system before disconnecting the hose Inspect pump hoses couplers and fitt...

Page 4: ...be connected to a permanent ground such as a properly grounded outlet box conduit or water pipe before plugging in the unit If extensions are used they should have sufficient rated capacity and a prop...

Page 5: ...Be sure to replace plug before refilling reservoir with oil Servicing Instructions Filling Oil Reservoir The oil reservoir must be kept filled with a good grade of light hydraulic oil Flushing System...

Page 6: ...place fuse Will not pump oil Not primed Run pump for a few minutes tipping unit from side to side Sticking plunger Replace 8 9 Plugged up screens Clean or replace 24 Defective control valve Repair or...

Page 7: ...sidiary of Textron Inc 7 4455 Boeing Dr Rockford IL 61109 2988 815 397 7070 1721 m4 Spec Hydraulic Power Pump Exploded View SERIAL NO LOCATION 12 50 12 12 43 A 9 25 2 18 21 10 75 2 68 56 62 53 63 64 6...

Page 8: ...ford IL 61109 2988 815 397 7070 1721 m4 Spec Hydraulic Power Pump Exploded View 1 2 3 4 HOLD POSITION PUMPING POSITION PUMP AND CYL TO TANK REMOVE SET SCREW BEFORE REMOVING MOTOR NOTE 69 59 61 58 70 1...

Page 9: ...g Dr Rockford IL 61109 2988 815 397 7070 1721 m4 Spec Hydraulic Power Pump Exploded View 22 37 26 20 4 25 19 40 1 B A B B 2 SECTION BB 38 28 4 23 36 29 26 7 33 9 8 22 41 13 3 34 5 32 6 35 30 10 24 18...

Page 10: ...Compression 1 23 501 4865 6 Spring Compression 1 24 502 1175 7 Screen Intake 1 25 905 0014 8 O Ring 5 8 x 3 4 x 1 16 1 26 905 0436 4 Ball 9 32 Grade 1 Chrome Steel 2 28 905 0677 4 Ball 5 32 Grade 1 C...

Page 11: ...905 0734 7 Plug 03 4 NPTF Socket Head Pipe 1 69 905 0824 6 Plug 1 16 NPT Socket Head Pipe 1 70 905 1269 3 Screw 1 4 20 NC x 1 4 Cup Point Head Set 1 71 905 1474 2 Screw 3 8 24 NF x 2 1 2 Socket Head...

Page 12: ...Printed in the U S A SOILTEST INC 86 Albrecht St Lake Bluff IL 60044...