SF-420AC

Working with Different Materials

The SF-420AC is for use on dry, interior walls only. Although the unit can scan
through up to 38 mm (1-1/2") of common construction materials in DeepScan
mode, three primary factors can affect sensing depth: thickness, density, and
moisture content.

This unit can scan effectively through most sheet materials, including:

• Bare wood flooring (in DeepScan mode)

• Linoleum on wood base

• Gypsum drywall over plywood sheathing

• Wallpapered walls (if dry)

• Textured ceilings if uniform thickness (Place a thin piece of cardboard on

ceiling and scan through it to avoid damage to texturing.)

The SF-420AC is not designed to scan materials with inconsistent density
such as:

• Ceramic floor tile

• Carpeting and padding

• Wallpaper with metallic fibers

• Freshly painted walls that are still damp (must dry at least a week)

• Lath and plaster walls

• Foil-covered insulation board

Note: Sensing depth and accuracy can vary due to moisture content of
materials, wall texture, and paint.

Troubleshooting

Specifications

Battery Type: 9 V alkaline

Estimated Battery Life: 1 year at 10 minutes per day with alkaline battery

SF-420AC Position Accuracy:

Stud Scan Mode: Typically within 3 mm (1/8") using the dual scan and

mark procedure

DeepScan Mode: Typically within 5 mm (3/16") using the dual scan and

mark procedure

SF-420AC Detection Depth:

Stud Scan Mode: Typically up to 19 mm (3/4")
DeepScan Mode: Up to 38 mm (1-1/2")
Note: Sensing depth and edge detection can vary due to moisture content

of materials, wall texture, paint, etc.

AC Position Accuracy: Typically 90 V to 250 V at 50 Hz to 60 Hz within 150 mm

(6") of a hot unshielded wire

AC Sensing Depth: In typical drywall with Romex

®

 wiring, wires can be

detected up to 76 mm (3") deep
Note: Sensing depth and position accuracy can vary due to moisture

content of materials, wall texture, paint, etc.

Operating Temperature: –7 

°

C to 49 

°

C (20 

°

F to 120 

°

F)

Storage Temperature: –29 

°

C to 66 

°

C (–20 

°

F to 150 

°

F)

Humidity: 80% RH (noncondensing)

Situation

Probable Causes

Solutions

• Turn unit off, move over a few inches, press On/Off button, and start

again.

• On rough surfaces, place piece of paper on wall, scanning through it to

help slide unit more smoothly.

• Keep hand at least 152 mm (6") from tool while you calibrate and scan.

Hold unit with thumb and index finger no higher than handgrips. Be
careful not to move your fingers after calibration.

• Always hold unit parallel to and move perpendicular to object you're

trying to locate.

Lights start flashing and unit
starts beeping.

• Scan began on dense part of wall or over a

stud.

• Unit not flat against wall.
• Unit tilted or lifted during scan.
(All these factors affect proper calibration.)

• Interpret red LED closest to center as stud edge.
• Switch to DeepScan to locate the stud.

Center green LED doesn't light in
Stud Scan mode.

Wall is particularly thick or dense.

• Hold unit so two Velcro™ strips on the back make contact with wall.
• Recalibrate unit in a different place and rescan area.

The green TruCal LED lights but,
when scanning, unit doesn't do
anything else.

• Unit may not be flat against the wall.
• If it is in the DeepScan mode (the DeepScan

LED is lit), you may have calibrated over a
stud.

Scanning surface is too dense or too wet for unit
to operate.

All three red LEDs and green LED
light at the same time and unit
beeps continuously.

If you are using unit on a recently taped, painted, or wallpapered wall,
allow time to dry and try again.

Working in DeepScan mode and
can't detect studs.

• You may have calibrated over a stud. (The

error condition is disabled in DeepScan mode
because it is twice as sensitive as Stud Scan.)

• You may be holding the unit like a TV remote,

aiming it at the wall.

• Move unit over a few inches and recalibrate.

• Hold unit so two Velcro strips on the back make contact with wall.

Detects other objects besides
studs.

Electrical wiring and metal or plastic pipes may
be near or touching back surface of wall.

• Remember that studs or joists are normally spaced 406 mm (16") or

610 mm (24") apart and are 38 mm (1-1/2") wide.

• Always turn off power when cutting, nailing, or drilling near electrical

wires.

• See above solution.
• Use extra caution if the area has plywood, thick wood backing behind

drywall, or thicker-than-normal walls.

• If a switch controls an outlet, make sure it is on for detection, but

turned off when working near electrical wires.

You suspect electrical wires, but
do not detect any.

• Wires may be shielded behind metallic wall

coverings, plywood shearwall, or other dense
material, or in conduit; unit may not be able to
find them.

• The wires may not be hot.
• Wires may be too deep to sense.

To narrow detection, turn unit off and on again at the edge of where wire
was detected and scan again.

Area of voltage detection is too
large.

Static charge may develop on drywall, spreading
voltage detection as much as 305 mm (12") from
each side of an actual electrical wire.

Summary of Contents for SF-420AC

Page 1: ...instructions and safety information in this manual before operating or servicing this tool Lea y entienda todas las instrucciones y la información sobre seguridad que aparecen en este manual antes de manejar esta herramienta o darle mantenimiento Lire attentivement et bien comprendre toutes les instructions et les informations sur la sécurité de ce manuel avant d utiliser ou de procéder à l entret...

Page 2: ...nailing cutting or drilling in walls floors and ceilings that may contain these items Failure to wear eye protection could result in serious eye injury from flying debris Electric shock hazard This tool will not detect hot wires inside metal pipe or conduit behind metallic wall covering or behind some plywood or other dense materials Always turn off power when nailing cutting or drilling near elec...

Page 3: ...er no higher than handgrips Be careful not to move your fingers after calibration Always hold unit parallel to and move perpendicular to object you re trying to locate Lights start flashing and unit starts beeping Scan began on dense part of wall or over a stud Unit not flat against wall Unit tilted or lifted during scan All these factors affect proper calibration Interpret red LED closest to cent...

Page 4: ...carse a un montante los indicadores LED rojos se iluminarán sucesivamente de abajo hacia arriba 6 Cuando el LED verde superior se ilumina la unidad emite un tono constante y el indicador SpotLite se enciende usted ha localizado el borde del montante Marque este punto 7 Continúe explorando más allá del punto marcado hasta que el LED verde se apague Deslice la unidad en la dirección opuesta para loc...

Page 5: ...libración Siempre mantenga la unidad paralela a y muévase en forma perpendicular al objeto que usted esté tratando de localizar Las luces comienzan a destellar y la unidad emite tonos Se inició la exploración en una parte densa de la pared o sobre un montante La unidad no está plana contra la pared Se inclinó o levantó la unidad durante la exploración Todos estos factores afectan la calibración co...

Page 6: ...ument successivement du bas vers le haut 6 Lorsque la DEL verte du haut s allume qu une tonalité continue se fait entendre et que SpotLite brille le bord d un montant est repéré Marquer cet endroit 7 Continuer le balayage au delà de la marque jusqu à ce que la DEL verte s éteigne Faire glisser l appareil en sens inverse pour repérer l autre bord du montant 8 Marquer ce deuxième endroit Le milieu d...

Page 7: ...oter et l appareil émet des bips La détection a commencé sur une portion épaisse du mur ou sur un montant L appareil n est pas bien à plat contre le mur L appareil est incliné ou soulevé pendant le balayage Tous ces facteurs influencent l étalonnage correct de l appareil Interpréter la DEL rouge la plus proche du centre comme indiquant le bord du montant Passer en mode DeepScan pour repérer le mon...

Page 8: ...ned to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular inst...

Reviews:

Related manuals for SF-420AC