Li’l Fisher
®
390 Power Fishing System
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
7
Operation
(cont’d)
Cleanup Vacuuming
Do not vacuum or blow burning or
toxic material such as carcinogens,
asbestos, pesticides or heavy metals.
Failure to observe this warning could
result in severe injury or death.
Wear eye protection and a dust mask
when operating the unit.
Failure to observe these warnings
could result in serious injury from
flying debris.
Do not use without a clean filter in place.
Do not pick up anything that is burning or smoking,
such as cigarettes, matches or hot ashes.
Failure to observe these warnings could result in
severe injury or death.
•
•
Wet Pickup
This unit is equipped with a shut-off float valve. When
used for wet pickup, the rising fluid lifts the float valve
until it seals against the motor intake. When this happens,
the sound of the motor changes to a higher pitch. Unplug
the unit, empty the tank, and replace the cover.
Dry Pickup
For optional dry pickup accessories, see the
Accessories at the end of the Parts List.
Maintenance
Removing and Installing Filter
Note: Keep filter clean. Efficiency of this vacuum is
largely dependent on the cleanliness of the filters.
A clogged filter can cause overheating and damage
to the motor. Filter should be removed and cleaned
periodically to ensure proper operation.
Filter
Rubber
Band
Latch
Wiring Diagram
50
35
36
8
Green cord lead
White cord lead
Black cord lead
White motor lead
Black motor lead
5
Motor
Rocker
switch
View from bottom of lid
Ground
58