background image

INSTRUCTION MANUAL

GT-12A Voltage Detector

52065734 

© 2013 Greenlee Textron Inc. 

3/13

Description

The Greenlee GT-12A Voltage Detector is intended to check for the presence 

of AC voltage, signaling the user with an intermittent tone and flashing LED. 

The tone can be disabled using the Smart ON/OFF button. The GT-12A has 

a Self Test feature that continuously tests the integrity of the entire unit 

including the antenna. The GT-12A also features low battery indication and 

an auto power off feature.
This tool is protected by U.S. Patent No. 7,733,078 and Canadian Patent No. 

2,607,922.

Safety

Safety is essential in the use and maintenance of Greenlee tools and 

equipment. This instruction manual and any markings on the tool provide 

information for avoiding hazards and unsafe practices related to the use of 

this tool. Observe all of the safety information provided.

Purpose of This Manual

This instruction manual is intended to familiarize all personnel with  

the safe operation and maintenance procedures for the Greenlee GT-12A 

Voltage Detector.
Keep this manual available to all personnel. Replacement manuals are 

available upon request at no charge at www.greenlee.com.

Do not discard this product or throw away!

  

For recycling information, go to www.greenlee.com.

All specifications are nominal and may change as design improvements occur. 

Greenlee Textron Inc. shall not be liable for damages resulting from misapplication 

or misuse of its products.
 ® Registered:  The color green for electrical test instruments is a registered 

trademark of Greenlee Textron Inc.
ROMEX is a registered trademark of Southwire Company.

Symbols on the Unit

Warning—Read the instruction manual
Double insulation

Important Safety Information

Read

 and 

understand

 this material before operating 

or servicing this equipment. Failure to understand how 

to safely operate this tool could result in an accident 

causing serious injury or death.

Electric shock hazard:
Contact with live circuits could result in severe injury 

or death.

Electric shock hazard:

Do not assume that no voltage indication means that the circuit 

is de-energized.

Follow the 3-point safety method as described in the “Operation” 

section (steps 3, 4, and 5).

• Do not use the unit if it is wet or damaged.
• Do not apply more than the rated voltage between the tip and earth 

ground.

• Do not operate with the case open.
• This tester will not detect voltage through metal conduit, on armored 

or shielded cable, on sheathed nonmetallic cable that is saturated 

with water, or at a distance such as through walls.

• Using this unit near equipment that generates electromagnetic 

interference can result in unstable or inaccurate readings.

Failure to observe these warnings could result in severe injury or death.

Electric shock hazard:
• Do not attempt to repair this unit. It contains no user-serviceable parts.
• Do not expose the unit to extremes in temperature or high humidity. 

Refer to “Specifications.”

Failure to observe these precautions may result in injury and can damage 

the unit.

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com

Reviews: