12
Accuracy
Refer to the “Specifications” section for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the r a fixed
amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 75% relative humidity.
Accuracy is specified from 5% to 100% of the range unless noted otherwise.
AC Voltage
Range
(40 Hz to 400 Hz)
Accuracy
Input Impedance
200.0 V
± (1.2% + 1.0 V)
450 kΩ
600 V*
± (1.2% + 10 V)
* 600 V range is specified from 20% to 100% of range.
DC Voltage
Range
Accuracy
Input Impedance
20.00 V
± (0.8% + 0.05 V)
1 MΩ
200.0 V
± (0.8% + 0.5 V)
600 V*
± (1.0% + 5 V)
* 600 V range is specified from 20% to 100% of range.
Resistance
Range
Accuracy
Open Circuit Voltage
200.0 Ω
± (1.2% + 0.5 Ω)
< 3 VDC
2000 Ω
± (1.0% + 5 Ω)
20.00 kΩ
± (1.0% + 0.05 kΩ)
200.0 kΩ
± (1.0% + 0.5 kΩ)
2000 kΩ
± (1.2% + 5 kΩ)
Summary of Contents for DM-25
Page 10: ...10 Typical Measurements AC Voltage Measurement Resistance Measurement 600 2000k ...
Page 16: ...16 ...
Page 25: ...DM 25 25 Mediciones más comunes Medición de tensión de CA Medición de resistencia 600 2000k ...
Page 39: ...DM 25 39 Mesures types Mesure de tension alternative Mesure de résistance 600 2000k ...
Page 53: ...DM 25 53 Typische Messungen Wechselspannungsmessung Widerstandsmessung 600 2000k ...