12
Accuracy
Refer to “Specifications” for operating conditions and temperature
coefficient.
Accuracy is specified as follows:
±
(a percentage of the r a
fixed amount) at 23
°
C
±
5
°
C (73.4
°
F
±
9
°
F), 0% to 80% relative
humidity.
AC Voltage
Frequency
Input
Range
Accuracy
Range
Impedance
199.9 V
±
(1.5% + 0.4 V)
45 to 400 Hz
0.5 M
Ω
300 V
±
(2.0% + 4 V)
DC Current
Range
Accuracy
Burden Voltage
1999
µ
A
±
(2.5% + 4
µ
A)
19.99 mA
±
(2.5% + 0.04 mA)
< 0.7 V
199.9 mA
±
(2.5% + 0.4 mA)
Resistance
Range
Accuracy
Typical Open Circuit Voltage
199.9
Ω
±
(1.5% + 0.5
Ω
)
3.2 VDC
1999
Ω
±
(1.5% + 0.005 k
Ω
)
19.99 k
Ω
±
(1.5% + 0.05 k
Ω
)
199.9 k
Ω
±
(1.5% + 0.5 k
Ω
)
> 0.3 VDC
1999 k
Ω
±
(2.0% + 0.004 M
Ω
)
DC Voltage
Range
Accuracy
Input Impedance
199.9 mV
±
(1.2% + 0.2 mV)
1.999 V
±
(1.2% + 0.002 V)
19.99 V
±
(1.2% + 0.02 V)
1 M
Ω
199.9 V
±
(1.2% + 0.2 V)
300 V
±
(1.5% + 2 V)
Summary of Contents for DM-20
Page 9: ...DM 20 9 Current Measurement Voltage Measurement Typical Measurements ...
Page 10: ...10 Typical Measurements Resistance Measurement Continuity Check ...
Page 11: ...DM 20 11 Diode Measurement Typical Measurements Reverse Bias Forward Bias Red Probe ...
Page 24: ...24 Medición de corriente Medición de tensión Mediciones más comunes ...
Page 25: ...DM 20 25 Mediciones más comunes Medición de resistencia Verificación de continuidad ...
Page 32: ...32 ...
Page 40: ...40 Mesure du courant Mesure de la tension Mesures types ...
Page 41: ...DM 20 41 Mesures types Mesure de la résistance Vérification de la continuité ...
Page 42: ...42 Sonde rouge Polarisation directe Polarisation inverse Mesure des diodes Mesures types ...