Identification

1.

+ terminal output to CMPL-100

2.

COM terminal output to CMPL-100

3.

Optical communication interface
to CMPL-100

4.

+ terminal input

5.

COM terminal input

6.

Standard D-shell 9-pin RS-232
communications connector

7.

Standard D-shell 9-pin to 25-pin
RS-232 communications adapter

8.

Standard 3-1/2 inch floppy disk for
PC compatible computer

Symbols on the Unit

Read the instruction manual.

Double insulation

7

6

8

2
1

3

5 4

CMPL-100

Summary of Contents for CMPL-100-1A

Page 1: ...3 0 1999 Greenlee Textron IM 1419 8 99 CMPL 100 1A RS 232 INTERFACE ADAPTER FOR CMPL 100 CLAMP ON METER Read and understand all of the instructions and safety information in this manual before operati...

Page 2: ...nance of Greenlee tools and equipment This instruction manual and any markings on the tool provide information for avoiding hazards and unsafe practices related to the use of this tool Observe all of...

Page 3: ...below indicates the severity of the hazard The message after the signal word provides information for preventing or avoiding the hazard SAFETY ALERT SYMBOL Immediate hazards which if not avoided WILL...

Page 4: ...ith live circuits can result in severe injury or death Electric shock hazard Do not use the unit if it is wet or damaged Use test leads or accessories that are appropriate for the application See the...

Page 5: ...can result in unstable or inaccurate readings Electric shock hazard Do not apply more than the rated voltage between any two input terminals or between any input terminal and earth ground Do not cont...

Page 6: ...MPL 100 4 terminal input 5 COM terminal input 6 Standard D shell 9 pin RS 232 communications connector 7 Standard D shell 9 pin to 25 pin RS 232 communications adapter 8 Standard 3 1 2 inch floppy dis...

Page 7: ...this program is compatible with Windows 3 0 only 8 letter filenames and directories are allowed When using the minimum hardware the fastest PC sampling rate allowed is 1 second Also only one logging f...

Page 8: ...pe in one of your choice or exit installation The necessary files will be copied to the specified destination The three files that will be placed in the POWER METER program group are POWER METER This...

Page 9: ...Run the program START PROGRAMS POWER METER POWER METER or START RUN C PWRMETER Pwrmeter exe 6 The program should automatically detect which serial communica tions port on the PC that the CMPL 100 1A a...

Page 10: ...a Logging Functions Real time data logging to disk Maximum and minimum data Set PC sampling rate 4 Data Logger of Meter Download CMPL 100 data Set time and date of data Store data in CMPL 100 Clear da...

Page 11: ...PC Data Logging Functions Display Data File Opens a window to view a previously saved file This software stores files with a DAT filename extension The data file will be opened as a list see Display L...

Page 12: ...nly be used for troubleshooting by a Greenlee qualified technician Option Undelete Memory Data This is an advanced user option This function lists all of the data presently in the meter s memory in a...

Page 13: ...CMPL 100 1A 13 2 Display Box Note Display is updated continuously while the meter is connected The frequency of data update can be changed see PC Data Logging Functions Units...

Page 14: ...quate disk space For example at a sampling rate of 2 seconds per data point 2Sec for ten hours of data logging 10 hours 60 minutes hour 60 seconds min 36000 seconds 3600 seconds 2 seconds data point 1...

Page 15: ...while turning meter on This date is used as a reference only for the user to track the date the data was recorded There is not a real time clock in the meter The date must enter in the format of MM D...

Page 16: ...16 The i button will reestablish communications with the meter This is useful if you forget to turn on the meter before you run the Power Meter program 5 Refresh Link with CMPL 100...

Page 17: ...and the POWER METER program is running click the Start Record button Both the meter and PC display will display Record To stop recording click the Stop Record button Q How do I transfer data from the...

Page 18: ...the computer the time of each data point will be calculated based on the recording date and time supplied and the record sampling rate NOTE The only way to change the recording date time and sampling...

Page 19: ...CMPL 100 1A 19...

Page 20: ...terial for their useful life excepting normal wear and abuse This warranty is subject to the same terms and conditions contained in Greenlee s standard one year limited warranty For all Test Instrumen...

Reviews: