Introduction

The 950-M3 Hydraulic Power Pump is a high-pressure
hydraulic power pump which is simple to operate,
lightweight, durable and portable.

This power pump has a built-in high volume / low
pressure pumping feature which gives fast approach
ram action and automatic changeover to low volume /
high pressure when pressure exceeds 100 psi. The
pumping unit consists of one piston, radial-type, capable
of developing 10,000 psi.

Assembly

The 950 Power Pump is completely assembled and is
shipped to you as a complete pumping unit. The only
assembly necessary is the connections of the ram to the
pump.

Operating Instructions

This pump is designed to operate at 10,000 psi inter-
mittently. For continuous service, such as production
work, the pressure should not exceed 6,000 psi. This
limitation is for engine protection only.

Before operating pump, check the following to assure
proper service:

1. The gasoline engine is shipped without oil or gaso-

line; refer to the manufacturer’s instruction manual
for recommended type and quantity before starting
engine.

2. Check tightness of hose connections before starting

engine.

3. Check hydraulic oil with dipstick (52). Oil should be

within 1/2" of reservoir top.

4. Start engine and allow the pump to idle a few min-

utes. This will allow the hydraulic oil to work into
moving parts and give prime to the pump.

Filling Oil Reservoir

In order for the pump to operate properly, the oil
reservoir must be kept filled with a good grade of light
hydraulic oil. Use Greenlee Hydraulic Oil 905 0806.8
(quart) or 905 1059.3 (gallon) or equivalent.

Eight quarts are required, of which 6-1/4 quarts are
usable. A minimum of 1-3/4 quarts must be at the
bottom of the reservoir at all times during operation.
Be sure that the complete operation does not require
more than the usable amount of oil.

To refill or add oil to the reservoir, proceed as follows:

1. Remove vent plug from top of reservoir.

2. Add oil to within 1/2" of reservoir top when ram is

retracted.

3. Install vent plug securely.

Note: Before operation, be sure vent plug is not

clogged.

Draining Oil Reservoir

Unscrew and remove 3/4 inch pipe plug (51) from side
of pump base. Turn pump on its side to drain all oil from
reservoir. Be sure to replace plug before refilling reser-
voir with oil.

Never use synthetic fluids or fluids with poor lubri-
cating qualities (i.e., brake fluids, etc.), as permanent
injury to the pump will result.

Service

Summary of Contents for 950-M3

Page 1: ...M 848 REV 3 8 97 950 M3 BASIC HYDRAULIC POWER PUMP Read and understand this material before operating or servicing this tool Failure to understand how to safely operate the tool could result in an accident causing serious injury or death Current for all pumps with Serial No code LC ...

Page 2: ...roperty damage Hazards or unsafe practices which if not avoided COULD result in severe personal injury or death Immediate hazards which if not avoided WILL result in severe personal injury or death SAFETY ALERT SYMBOL The symbol above is used to call your attention to instructions concerning your personal safety Watch for this symbol It points out important safety precautions It means ATTENTION Be...

Page 3: ... system or system component other than those supplied by Greenlee and rated at less than 10 000 psi 68 950 kPa Do not alter the internal high pressure relief valve setting Do not use this pump in a hazardous environment Hazards include open flame and flammable liquids or gases Failure to observe these warnings will result in severe injury or death Skin Injection Hazard High pressure oil easily pun...

Page 4: ...tarting engine 2 Check tightness of hose connections before starting engine 3 Check hydraulic oil with dipstick 52 Oil should be within 1 2 of reservoir top 4 Start engine and allow the pump to idle a few min utes This will allow the hydraulic oil to work into moving parts and give prime to the pump Filling Oil Reservoir In order for the pump to operate properly the oil reservoir must be kept fill...

Page 5: ... entire oil system should be flushed as follows 1 Drain oil from reservoir 2 Fill reservoir with any recommended flushing oil or clean kerosene and operate pump Work the control handle back and forth several times during flushing to wash all foreign particles from the control valve unit Note Do not operate pump for a very long time as system is not designed to operate with flushing oil or kerosene...

Page 6: ...w 68 Necessary to add oil often Oil leaks Check for broken lines loose fittings or connections If the above corrective measures fail to make the pump function properly it is recommended that you send the pump back to the factory or to an authorized Greenlee service center Under no conditions allow unqualified personnel to attempt to repair the pump particularly the pump block unit or control valve...

Page 7: ... Rockford IL 61109 2988 815 397 7070 Greenlee Textron Subsidiary of Textron 950 M3 Basic Hydraulic Power Pump 60 SERIAL NO LOCATION A A 15 50 11 43 9 25 10 75 4 3 69 58 56 67 70 21 68 65 66 55 59 61 64 54 62 63 57 53 A ...

Page 8: ...ng Dr Rockford IL 61109 2988 815 397 7070 950 M3 Basic Hydraulic Power Pump B A B B 22 26 37 9 8 7 33 36 29 23 38 28 27 4 31 3 34 5 6 32 20 10 13 SECTION A A 22 37 26 20 4 25 19 40 1 2 SECTION BB 35 30 10 24 18 15 12 17 16 11 14 39 40 ROTATION 096 106 ...

Page 9: ...llow 1 19 905 1473 4 Bearing single row unshielded ball 1 20 501 8237 4 Block pump 1 21 502 2701 7 Adapter drive shaft 1 22 500 6111 9 Spring compression 1 23 501 4865 6 Spring compression 1 24 502 1175 7 Screen intake 1 25 905 1472 6 Lok dowel 1 4 x 3 4 2 26 905 0436 4 Ball steel 9 32 diameter 2 27 501 8195 5 Plunger check valve 1 28 905 0677 4 Ball steel 5 32 diameter 1 29 905 0681 2 Ball steel ...

Page 10: ... 1 Seal oil 1 375 x 2 375 x 312 1 60 905 0734 7 Plug pipe 3 4 NPTF socket 1 61 905 0505 0 Washer lock 323 x 586 x 078 spring 3 62 905 0506 9 Washer lock 388 x 673 x 070 steel 4 63 905 0522 0 Screw cap 5 16 18 UNC x 1 hex head 2 64 905 0523 9 Screw cap 5 16 18 UNC x 1 1 4 hex head 3 65 905 0228 0 Screw cap 5 16 18 UNC x 1 1 2 socket head 1 66 905 0387 2 O ring 437 x 625 x 093 1 67 502 0330 4 Washer...

Reviews: