![Greenlee 35346 Instruction Manual Download Page 26](http://html1.mh-extra.com/html/greenlee/35346/35346_instruction-manual_2262366026.webp)
6000-Series Super Tugger Cable Pullers
Greenlee Tools, Inc.
26
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
Maintenance
Read all instructions thoroughly. Be sure that you
understand all of the instructions and have the
necessary tools available before dismantling the puller.
Service Activity
Schedule
Lubricate the drive chains.
every 20 hours
Grease the drive chain shafts.
every 20 hours
Inspect the chains and ratchet pawl. every 40 hours
Inspect the commutator brushes.
every 40 hours
Lubricating the Drive Chains (every 20 hours)
1. Remove the right outer guard (71) and left outer
guard (4).
2. Lubricate the inside of the chains with 80W-90W
gear oil.
3. Replace the guards and screws.
Greasing the Drivetrain Shafts (every 20 hours)
Apply a multipurpose NLGI Grade 2 grease (such as
Mobilgrease
®
HP or Amoco Permalub) at the grease
fittings (5 and 52). These fittings are located inside the
capstan housing and under the countershaft (47).
Electric shock hazard:
Disconnect the cable puller from
the power supply before servicing.
Failure to observe this warning can
result in severe injury or death.