Ceiling Exhaust Fans

1

®

Document 485101

Models SP-LP0511 and SP-LP0511L 

Ceiling Exhaust Fans

Installation, Operation and Maintenance Manual

Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, 
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure 
to comply with these instructions will result in voiding of the product warranty and may result in personal injury 
and/or property damage.

General Safety Information 

Only qualified personnel should install this fan. 
Personnel should have a clear understanding of these 
instructions and should be aware of general safety 
precautions. Improper installation can result in electric 
shock, possible injury due to coming in contact with 
moving parts, as well as other potential hazards. 
1.  Do not install this ventilation fan where interior room 

temperature may exceed 104°F (40°C).

2.  Make sure that the electric service supply voltage is 

AC 120V, 60Hz.

3.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the National 
Fire Protection Agency (NFPA), where applicable. 
Follow the Canadian Electric Code (CEC) in Canada.

4.  Always disconnect the power source before working 

on or near the fan, motor, light fixture, or junction 
box.

5.  Protect the power cord from sharp edges, oil, 

grease, hot surfaces, chemicals or other objects.

6  Do not kink the power cord.
7.  Do not install the unit where ducts are configured as 

shown in Fig. 1.

8.  Provide make up air for proper ventilation

MultiSpec SP-LP0511

MultiSpec SP-LP0511L

Table of Contents

Features . . . . . . . . . . . . . . . . . . . . . . . . 1
Supplied Accessories . . . . . . . . . . . . . . . . . 2
Dimensional Data  . . . . . . . . . . . . . . . . . . . 2
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . 3
Installation for Joist Mounting . . . . . . . . . . . . . 4
Installation for Wall Mounting . . . . . . . . . . . . . 6
Maintenance .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   7
Typical Installation . . . . . . . . . . . . . . . . . . . 8
Replacement Parts List  . . . . . . . . . . . . . . . . 8

MultiSpec Ceiling Exhaust Fan

Model SP-LP is a direct drive wall/ceiling exhaust fan 
designed for clean air applications where low sound  
levels are required. Accessories include lights, flow 
selection, and constant airflow. These models are  
ETL listed. 

Duct

Adaptor

Duct

Adaptor

Fig. 1

Duct

Adaptor

Duct

Adaptor

Features

High Energy Efficiency

The fan uses a brushless DC motor to ensure a high 
energy efficiency.

Constant Air Flow

Duct length, elbows and other factors increase static 
pressure and negatively impact the performance of 
most ventilation fans. This fan utilizes adaptive Constant 
CFM technology that monitors the static pressure in the 
system and speeds up or slows down the rpm of the 
motor depending upon the amount of resistance within 
the ducts. The fan will perform at the rated airflow and 
helps avoid potential installation issues.

Flow Selection

Fans are supplied with a flow selection switch which 
can be set to 50, 80, or 110 CFM.

Air volume option (cfm)

Factory setting

50

80

110

110

Air volume

50   80   110

Air volume

50  80  110

Summary of Contents for MultiSpec SP-LP0511

Page 1: ...otect the power cord from sharp edges oil grease hot surfaces chemicals or other objects 6 Do not kink the power cord 7 Do not install the unit where ducts are configured as shown in Fig 1 8 Provide m...

Page 2: ...1 8 308 2 1 2 64 10 2 5 265 3 3 4 95 3 1 2 88 13 330 Unit inches mm Supplied Accessories or Grille Qty 1 Long screw ST4X30 Qty 5 SP LP0511 SP LP0511L No Part Name No Part Name 1 Wheel 6 Knockout plat...

Page 3: ...o a value greater than R40 45 45 Do not install fan in this area Fig 2 ATTENTION utiliser pour la ventilation g n rale uniquement Ne pas utiliser pour l aspiration de mati res et vapeurs dangereuses o...

Page 4: ...body See Fig 4 3 Utilize 4 inch circular duct to connect to duct adapter on the fan housing Squeeze the circular duct to fit the adapter and secure it with clamps or ties and seal it with mastic or ap...

Page 5: ...ings into slots as shown and mount grille to fan body See Fig 7 and Fig 8 6 For model SP LP0511L with light a Insert the grille mounting spring on the wiring side into the slot insert the plug into th...

Page 6: ...lation As shown below ATTENTION The duct adapter of product must be installed upward 2 Complete the wiring and duct work please refer to steps 2 and 3 of Joist Mounting Installation page 4 to complete...

Page 7: ...ater over 140 F 60 C Cleaning 1 Remove grille Squeeze mounting spring and pull down carefully See Fig 11 2 Clean grille Do not put into hot water Use non abrasive kitchen detergent wipe dry with clean...

Page 8: ...ed with existing ducts may not achieve their rated airflow Rigid metal duct is recommended for optimal fan performance Ensure duct joints and exterior penetrations are sealed with caulk or other simil...