Greenheck Grease Grabber 474753 Installation, Operation And Maintenance Manual Download Page 12

12

474753 • Grease Grabber Triple Play, Rev. 1, September 2011 

Copyright 2011 © Greenheck Fan Corp.

Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from 

the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option 

when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of 

one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the 

nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs.

As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications 

without notice.

®

Phone: (715) 359-6171 • Fax: (715) 355-2399 • E-mail: [email protected] • 

Website: www.greenheck.com

Warranty

AMCA Publication 410-96, Safety Practices for Users and 

Installers of Industrial and Commercial Fans, provides 

additional safety information. This publication can be 

obtained from AMCA International, Inc. at: www.amca.org.

Greenheck Grease Grabber Triple Play catalog provides 

additional information describing the equipment, fan 

performance, available accessories, and specification data.

Summary of Contents for Grease Grabber 474753

Page 1: ...afety precautions Improper installation can result in electric shock possible injury due to coming in contact with moving parts as well as other potential hazards Other considerations may be required if high winds or seismic activity are present If more information is needed contact a licensed professional engineer before moving forward Follow all local electrical and safety codes as well as the N...

Page 2: ...ry atmosphere Remove any accumulations of dirt water ice or snow and wipe dry before moving to indoor storage To avoid sweating of metal parts allow cold parts to reach room temperature To dry parts and packages use a portable electric heater to get rid of any moisture buildup Leave coverings loose to permit air circulation and to allow for periodic inspection OUTDOOR Units designed for outdoor ap...

Page 3: ...ion 5 Start Up 5 Filter Status Indicator 5 Filter Replacement 6 Carbon Panel Replacement 6 Maintenance 6 Regular Scheduled Maintenance 6 Replacement Filter Parts Ordering 6 Figures 1 and 2 7 Wiring Diagram 8 9 Maintenance Log 10 11 Warranty 12 NOTE Grease Grabber Triple Play must be connected to a listed exhaust hood assembly and must be installed in accordance with local building codes NFPA 96 an...

Page 4: ... Materials Ducts shall be constructed of and supported by carbon steel not less than 1 37 mm 0 054 in No 16 MSG in thickness or stainless steel not less than 1 09 mm 0 043 in No 18 MSG in thickness Installation All seams joints penetrations and duct to hood collar connections shall have a liquid tight external weld An inlet transition is furnished to match the inlet duct size The inlet transition ...

Page 5: ... in the proper sequence and proper direction of airflow for filter stages 1 2 3 stage 4 carbon panels are not subject to airflow direction Open the access doors Remove the filter compression plates at stages 1 2 3 4 Install filters and replace all 4 filter compression plates Compression plates must be in place to ensure proper filter sealing integrity Close and latch access doors Operation NOTE Pr...

Page 6: ...odor breakthrough is first noticed When replacing carbon panels follow the instructions in the Operation section Filter Replacement Steps 2 10 There is no particular direction of airflow for carbon panels R R R CHANGE PRE FILTER CHANGE BAG FILTER CHANGE RIGID FILTER REMOTE FILTER STATUS INDICATOR R R R CHANGE PRE FILTER CHANGE BAG FILTER CHANGE RIGID FILTER REMOTE FILTER STATUS INDICATOR Maintenan...

Page 7: ...ED STAGE 1 FILTER COMPRESSION PLATE STAGE 2 FILTER COMPRESSION PLATE STAGE 3 FILTER COMPRESSION PLATE STAGE 4 FILTER COMPRESSION PLATE ON OFF DISCONNECT Elevation View INLET TRANSITION OPTIONAL STAGE 3 FILTER PRESSURE SWITCH ENCLOSURE ACCESS DOOR SIDE STAGE 1 FILTER STAGE 2 FILTER STAGE 4 FILTER ACCESS DOOR ON OFF DISCONNECT Elevation View ...

Page 8: ... CIRCUIT BREAKER 1101 L1 130CR1 L2 130CR2 T1 1102 T2 1122 112M L3 130CR3 T3 1142 122 T 0 5A 1102 H4 50VA FAN MOTOR 208 230 460V 60HZ 3PH 1725 RPM STEPDOWN TRANSFORMER PRIMARY FUSE 1301 1261 1261 124 126 128 130 132 130 SW OFF 4 3 ON XOO 1301 1TB2 124FU 0 6A 96 130CR4 1301 1TB5 1301 95 G 128 LT X1 X2 1262 1262 2TB1 C 130CR A1 1302 A2 1262 2TB2 INDICATOR LIGHT PRIMARY POWER 110 112 114 126 FAN CONTR...

Page 9: ...61 3TB 2 1261 3TB 1 1261 4TB 1 1262 4TB 2 1262 4TB 3 1262 SERIES ADPS 05 2 N READ ACROSS BAG FILTER PRESSURE SWITCH SERIES ADPS 05 2 N ADJUSTABLE DIFFERENTIAL READ ACROSS RIGID FILTER PRESSURE SWITCH ADJUSTABLE DIFFERENTIAL NC NO 1 COM 3 2 NC NO 144DPS COM 3 1 2 3TB 6 1441 SERIES ADPS 03 2 N ADJUSTABLE DIFFERENTIAL PRESSURE SWITCH READ ACROSS PREFILTER COM NO NC 140DPS 1 136DPS 3 2 1401 3TB 5 1361...

Page 10: ...____________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ______________________...

Page 11: ...____________________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes ___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ______________...

Page 12: ...be returned to the nearest authorized motor service station Greenheck will not be responsible for any removal or installation costs As a result of our commitment to continuous improvement Greenheck reserves the right to change specifications without notice Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo greenheck com Website www greenheck com Warranty AMCA Publication 410 96 Safety Practices fo...

Reviews: