background image

Specifications

Backdraft dampers meeting the following specifications shall 
be furnished and installed where shown on plans and/or as 
described in schedules. Dampers shall consist of: heavy gauge 
6063T5 extruded aluminum channel frame (0.125 in.[3.2mm] 
thick) with 3

1

Ú

8

 in. (79mm) depth; blades from 0.070 in.(1.8mm) 

6063T5 extruded aluminum; 

3

/

4

 in. (19mm) dia. metallic axles 

turning in acetal bearings; damper shall be equipped with 
extruded vinyl blade seals; and internal 

1

/

8

 in. (3mm)  plated 

steel blade-to-blade linkage. Damper manufacturer’s printed 
application and performance data including pressure, velocity 
and temperature limitations shall be submitted for approval 
showing damper suitable for pressures to 10 in. wg (2491 Pa), 
velocities to 3500 fpm (18 m/s) and temperatures to 180°F 

(82ºC). Testing and ratings to be in accordance with AMCA 

Standard 500-D. Basis of design is Greenheck model EM-40.

Velocity (fpm)

1

x 10

Pr

essur

e Loss ( 

In. 

w

g

)

10

9

8

7
6
5

4

3

2

  2          3      4      5   6   7    8  9 10

1.0

.9

.8

.7
.6
.5

.4

.3

.2

.10

.09

.08

.07
.06
.05

.04

.03

.02

x 100

  2          3      4      5   6   7    8  9 10

x 1000

  2          3      4      5   6   7    8  9 10

Pressure Drop

Performance data results from testing a 36 in. x  36 in. 

(914mm x 914mm) damper in accordance with AMCA Standard 
500-D using Figure  5.7A (unducted). All data has been corrected 

to represent standard air at 0.075 lb/ft

3

 (1.201 kg/m

3

).

Pressure Limitations

Velocity Limitations

Pr

essur

e (in. w

.g.)

48

36

24

12

0

8

6

4

2

0

4.0 in. w.g.

6.0 in. w.g.

Damper Width (in.)

10

8.0 in. w.g.

10.0 in. w.g.

0

12

24

36

48

0

60

74

3000 fpm

2500 fpm

Damper Height (in.)

Damper Width (in.)

3500 fpm

36

140

1.0

.9
.8
.7

.6

.5

.4

.3

.2

6

5

4

3

2

Static Pr

essur

e Dif

fer

ence

Air Leakage in CFM/Sq. Ft.

1                                 2                 3           4            5     6      7      8    9  1 0

 20         30      40      50   60

Static Pr

essu

re

 Di

ff

er

ence

1.0

.9

.8
.7
.6

.5

.4

.3

.2

10

9

8
7
6

5

4

3

2

Air Leakage in CFM/Sq. Ft.

1                 2         3     4      5   6   7   8  9  10

 20         30     40      

50   60   70   80  90 100     150

EM-10

Air Leakage in CFM/Sq. Ft.

1                 2         3     4      5   6   7   8  9

10

 20         30     40      

50   60   70   80  90 100     150

1.0

.9
.8
.7
.6

.5

.4

.3

.2

8.5

8
7
6

5

4

3

2

Static Pr

essur

e Dif

fer

ence

130

Wit

S

eal

s

W

ith

ou

t S

ea

ls

Leakage testing was conducted in accordance with AMCA 

Standard 500-D and is expressed as CFM per sq. ft. of damper 

face area. All data has been corrected to represent standard air 

at 0.075 lb/ft

(1.201 kg/m

3

).

Leakage

36 in. x 36 in. Damper

Copyright © 2008 Greenheck Fan Corporation

EM-40  Rev 4 Aug 2008

Performance Data                                             EM-40

Operational Data

ÆP in. wg 

(Pa)

Veloc-

ity fpm 

(m/s)

Damper with Standard 

Bearings

Blades Start to Open

0.07 (17)

50 (.254)

Blades Fully Open

0.20 (50)

1200 (6.2)

Reviews: